4
User's Manual
High Velocity Hand Dryer
1200MM
[47 1/4"]
1200MM
[39 3/8"]
It is recommended to avoid installation of
dryer near high reflective objects
(mirror, stainless steel washbasins, etc.) in
order to avoid faulty function of the presence
sensor.
Recommeded
L Min. = 300MM[11-13/16"]
42MM[1-21/32"]
71MM[2-51/64"]
98MM
[3-55/64"]
91MM[3-37/64"]
If hand dryer is to be installed with hardwired stub
provided in advance of install by others. See MT for
complete reference to mounting heights and power KO
locations.
120V/16A
BBEEFFOORREE IINNSSTTAALLLLAATTIIOONN
Installation must be carried out in accordance with the current edition of the local wiring regulations code. Installation
should be performed only by a qualified electrician.
IINNSSTTAALLLLAATTIIOONN
1. Make sure power supply breaker is switched off. Installation must adhere to the regulations of the current edition of the
local wiring code having jurisdiction. Installation should be
performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations on MT) and mark locations of
four(4) mounting holes and wire service entry at knockout (KO) location. NNoottee: For two(2) or more dryers units, units
should be no closer than 610MM[24"] on centers.
3. Remove and retain 2 cover screws and cover.
4. a. For in-wall (concealed) power supply-
Provide supply wire to KO location according to local code and attach securely to chassis at KO
with appropriate strain relief connector (not supplied).
b. For surface Mounted Conduit (exposed) power supply -
Provide appropriate conduit to entry location accordingly to local code and attach securely to chassis with correct
strain relief connector (not supplied).