background image

412587 

www.globalindustrial.com 

412586 Indicator 

Instruction Manual 

Contents subject to change without notice 

Version 1.0 

Issue AA

 

Summary of Contents for 412586

Page 1: ...412587 www globalindustrial com 412586 Indicator Instruction Manual Contents subject to change without notice Version 1 0 Issue AA...

Page 2: ...er manual 2 Accurate test weights see the CALIBRATION section of the user manual for the quantity of weights necessary to calibrate the scale 3 The technical ability to perform the setup of the scale...

Page 3: ...412586 www globalindustrial com 2 Connect the new indicator to the scale base This is only a reference scale base picture your scale base maybe a different one...

Page 4: ...s to move once up the BMI is to move once down the TARE PRESET key is to move once enter and to accept exit and the ZERO ON OFF key twice is to EXIT the CONFIG MODE Now let s go back to the next subme...

Page 5: ...settings as the column shows Only PRIM N PRIM D SECND N parameters need to be set the other parameters have already been pre set at the factory for this indicator CONFIG SubMenu1 SubMenu2 Option 2447...

Page 6: ...tting 244293 Setting MOTION 1 255 4 4 OVER LD 0 100 0 0 AD FROM ADC ADC ADC COM3 AD H SPD NO NO NO YES UNITS KG YES YES YES NO LB YES YES YES NO OZ YES NO NO NO LB OZ YES no no NO G YES NO NO NO ZRO P...

Page 7: ...ting ZRO PNT OV IZSM DSP OVR DSP OVR DSP OVR WEIGHT CAL ZRO LAST Z T SAZSM 0 100 20 20 AZSM 0 100 56 56 FILTER FLT1 TH 0 255 40 40 FLT1 ST 1 64 8 8 FLT2 TH 0 255 8 8 FLT2 ST 0 255 240 240 FUNC HOLD YE...

Page 8: ...10 of the total capacity You need another that is more than the first but less than the total capacity Let s use an example You have a 440 lb total capacity scale You have a box full of bolts that by...

Page 9: ...e lb Change the weight on the indicator to match the weight that you have out on the scale in the example above this would be 56 6 lbs Once this is done press TARE PRESET The scale will calculate and...