background image

15

Stainless Steel Drum Scale

5. OPERATIONS

Change working mode

Press and hold the 

PRINT/FUNC

 key, then use 

key to choose and confirm 

to enter into weighing mode or counting mode. 

Normal Weighing Mode

1. Power on the scale by pressing the 

ZERO/ON/OFF

 key. 

2.

If the display stabilizes but doesn‟t show zero, press the 

ZERO/ON/OFF

 key to set new 

zero point. 

3. Place objects on the scale platform and read the weight on the indicator.

Note: 

Objects should be placed at the center of the platform. Corner or side loading

heavy objects may risk overloading an individual load cell and damage the scale.

Yes

No

No

4. To change the weight unit of measure, press the 

UNIT/DATA

 key.

Note: under certain conditions, g and lb:oz are not available. In trade applications, lb:oz

should be prohibited. Please refer the following 

tables (5-1 and 5-2).

5. To send data to another device via the serial port, press the 

PRINT/FUNC

 key. 

6. Power off the scale by pressing and holding the 

ZERO/ON/OFF

 key for 4 seconds. 

Table5-1: use Kg as primary unit: 

Calibration 

division value

Display division value in different weight unit that can be used

kg

g

lb

oz

lb:oz

0.0001kg

0.0001kg

0.1g

0.0002lb

0.005oz

Not available

0.001kg

0.001kg

1g

0.002lb

0.05oz

Not available

0.01kg

0.01kg

10g

0.02lb

0.5oz

0.5oz

0.1kg

0.1kg

100g

0.2lb

5oz

Not available

1kg

1kg

Not available

2lb

50oz

Not available

10kg

10kg

Not available

20 lb

Not available

Not available

0.0002kg

0.0002kg

0.2g

0.0005 lb

0.01oz

Not available

0.002kg

0.002kg

2g

0.005 lb

0.1oz

0.1 oz

0.02kg

0.02kg

20g

0.05 lb

1oz

1 oz

0.2kg

0.2kg

200g

0.5 lb

10oz

Not available

2kg

2kg

Not available

5 lb

Not available

Not available

20kg

20kg

Not available

50 lb

Not available

Not available

0.0005kg

0.0005kg

0.5g

0.001 lb

0.02oz

Not available

0.005kg

0.005kg

5g

0.01 lb

0.2oz

0.2 oz

0.05kg

0.05kg

50g

0.1 lb

2oz

2oz

0.5kg

0.5kg

500g

1 lb

20oz

Not available

5kg

5kg

Not available

10 lb

Not available

Not available

50kg

50kg

Not available

Not available

Not available

Not available

User Manual

Summary of Contents for 412584

Page 1: ...usuario Manuel de l utilisateur Customer Service US 1 800 645 2986 Servicio de atenci n al Cliente US 1 800 645 2986 Service la client le Canada 888 645 2986 Models 412584 Stainless Steel Drum Digita...

Page 2: ...Setup Mode 9 Main menu 9 USER Submenu 10 5 OPERATIONS 15 Change working mode 15 Normal Weighing Mode 15 ZERO 16 Setting a Tare Weight 16 Setting a Pre Determined Tare Weight 16 Check Weighing Data Co...

Page 3: ...ons table Allow the scale to acclimate to room temperature before using Allow sufficient warm up time Turn the scale on and allow up to 2 minutes for internal components to stabilize before weighing E...

Page 4: ...it t lb kg D Di is sp pl la ay y 6 digit 7 segment 1 25mm LCD with backlight Z Ze er ro o R Ra an ng ge e Programmable zero range T Ta ar re e R Ra an ng ge e Full capacity S St ta ab bi il li iz za...

Page 5: ...600mA adapter Indicator Manual U Un np pa ac ck ki in ng g a an nd d I In ns st ta al ll la at ti io on n Place the scale platform on a hard floor and level the feet Connect the indicator to the platf...

Page 6: ...6 Stainless Steel Drum Scale 3 OVERVIEW OF CONTROLS AND FUNCTIONS Indicator Display Character Definitions User Manual...

Page 7: ...ng mode Hold type is PEAK HOLD lb Measure unit is lb or lb oz oz Measure unit is oz or lb oz kg Measure unit is kg Measure unit is in percentage weighing mode Pcs Measure unit is pieces in counting mo...

Page 8: ...hing mode 3 seconds Changes weighing unit of measure Counting or Percent mode 3 seconds Enters the submenu to input piece weight for counting or to enter reference weight for percent weighing Weighing...

Page 9: ...main menu item then press the T TA AR RE E P PR RE ES SE ET T key to enter the item use key to select the submenu item to select a choice to set a number to confirm and save data and or to exit this m...

Page 10: ...ed or request command received S ST TA AB BL LE E output after scale is stable N No ot te e use PRINT or CMD to output data the scale must be stable P Pr rt tc cm md d C CO ON NT T P PR RI IN NT T C C...

Page 11: ...pt is STATUS N NO O N NO O B B L LI IN NE E N NO ON NE E How many blank lines after strings output NONE no blank line LINE1 2 3 4 there re 1 2 3 or 4 blank lines after strings used for paper feed forw...

Page 12: ...Yes No enable disable output weight of 1 percentage Prompt is 1 REF WT N NO O N NO O C CO OU UN NT T Y YE ES S Yes No enable disable output counts Prompt is QUANTITY N NO O N NO O P PW WT T Y YE ES S...

Page 13: ...il press HOLD key again to exit AVERAG Average HOLD mode in this mode if weight is over NLD RNG and its variation is less than HLD RNG the average data in AVG TIM will be frozen Press HOLD key or HLD...

Page 14: ...time 0 not auto power off 1 255 auto power off after 1 255 minutes in this period no operation or no weight changing 5 5 O OF FF F M MD D O OF FF F Auto off mode OFF turn off instrument DSP TIM displa...

Page 15: ...6 Power off the scale by pressing and holding the ZERO ON OFF key for 4 seconds Table5 1 use Kg as primary unit Calibration division value Display division value in different weight unit that can be...

Page 16: ...t available 50 lb Not available Not available ZERO If the display does not show 0 and there is no an object on the platform press the ZERO ON OFF key to zero the reading Zero range 2 full Capacity The...

Page 17: ...d move to the next step 4 Low will be displayed quickly the last Lo limit value will be displayed the default value is 000000 LO on the display will be lit Use the keys to input the lower limit of the...

Page 18: ...quantity of the load that has been weighed 1 From normal weighing mode or percent weighing mode press and hold the P PR RI IN NT T F FU UN NC C key for 4 seconds Use the keys to select C CO OU UN NT T...

Page 19: ...n after powering off The indicator can only save one piece weight Entering a new piece weight will automatically replace the old one C Ch he ec ck k C Co ou un nt ts s c co ou un nt ts s c co om mp pa...

Page 20: ...play number if the scale is stable If the scale is not stable but the variation is less than U US SE ER R H HO OL LD D H HL LD D R RN NG G the scale will average data in U US SE ER R H HO OL LD D A AV...

Page 21: ...eak HOLD mode the P PE EA AK K and H HO OL LD D announciator will be lit and for other HOLD modes the H HO OL LD D announciator will be lit When H HO OL LD D announciator is flashing the displayed num...

Page 22: ...ror 1 calibration error 1 initial zero error 1 low battery 4 always 1 always 1 always 1 always 1 5 always 1 always 1 always 1 always 1 6 always 0 always 1 always 1 always 0 7 parity parity parity pari...

Page 23: ...C CR R 58h 0dh Response power off the scale just like press down the off the scale viii Command all others Response Unrecognized command LF CR ETX b Summary of Command and Response C Co om mm ma an nd...

Page 24: ...yte of string frame b Layout examples when U US SE ER R O OU UT T1 1 2 2 x xx xx xx x is set to Y YE ES S I In n w we ei ig gh hi in ng g m mo od de e SCALE ID GROSS TARE NET ACC N TOTAL DATE TIME A D...

Page 25: ...ame as W above K K 4b Switch to and send metric weight Same as W above others Un known commands STX Status Byte CR 9 Communication Details when U US SE ER R C CO OM M1 1 2 2 L LA AY YO OU UT T is set...

Page 26: ...ponse Command Response ASCII HEX W CR 57 0D Returns decimal lb kg or oz weight units and status LF pxxx xxUU CR hh ETX Returns ounces weight with units plus scale status LF p00xxxxxOZ CR hh ETX Scale...

Page 27: ...the scale and press the TARE PRESET key to confirm the Z ZE ER RO O will flash when it is in the catching zero point state After receiving reasonable data it will automatically continue to step 8 Lin...

Page 28: ...sed on C CA AL L P P2 2 onto the scale The next operation steps are the same as explained in step b g When the stable and reasonable data corresponding to the standard weight has been received the ind...

Page 29: ...29 Stainless Steel Drum Scale TABLE6 1 Location Code for different elevation and latitude User Manual...

Page 30: ...e display Format is xx xx xx hh mm ss 24h format 3 Press and hold the UNIT DATA key for more than 4 seconds to enter modification time mode Using keys to modify current time If inactivity exceeds 5 se...

Page 31: ...ght reading below Power On Zero limit 1 Install platform on the scale 2 Check whether an object stuck between the load cell and scale base if yes remove the object 3 Perform zero calibration 1 Weight...

Page 32: ...uring units missed CONFIG parameters are not correctly set Re set CONFIG parameters per the Technical Manual Incorrect counting result or percent weighing result when using SPL to enter a piece weight...

Page 33: ...nless Steel Drum Scale 1 10 0 R Re ep pl la ac ce em me en nt t p pa ar rt t P Pa ar rt t N Nu um mb be er r D De es sc cr ri ip pt ti io on n 318529 AC adapter 9V 600mA 412587 Display Indicator User...