English
I NS TA LL AT ION MA NU AL
24
Gastype:
Indirect heating functionality
Direct heat output
Indirect heat output
Space heating emissions NO
x
Heat output
Nominal heat output
Minimum heat output (indicative)
Technical data
Nominal heat input (Hs)
Nominal heat input (Hi)
Consumption max
Consumption min
Burner pressure max
Burner pressure min
Main burner injector
Low setting injector
Efficiency class (EN613)
Useful efficiency (NCV)**
Useful efficiency at nominal heat output
Useful efficiency at minimum heat output
(indicative)
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
In standby mode
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable)
Energy efficiency
Energy efficiency index
Energy efficiency class
Symbol
P
nom
P
min
η
th,nom
η
th,min
el
max
el
min
el
SB
P
pilot
EEI
G25/G25.3*
No
5,3
-
86,3
5,3
3,1
7,0
6,3
755
460
18,3
6,7
2x Ø1,15
2x Ø1,00
Ø1,80
1
92,3
90,5
-
-
-
-
92,3
A
G20
No
5,7
-
103,7
5,7
3,4
7,4
6,6
699
432
14,6
5,4
2x Ø1,15
2x Ø1,00
Ø1,80
1
92,7
91,3
-
-
-
-
92,7
A
G31
No
5,5
-
92,7
5,5
3,2
7,2
6,6
266
160
24,6
8,5
1xø0,70 1xø0,65
2x ø 0,85
Ø1,35
1
92,4
89,1
-
-
-
-
92,4
A
Unit
kW
kW
mg/kWh
input
(GCV)
kW
kW
kW
kW
L/h
L/h
mbar
mbar
mm
mm
%
%
kW
kW
kW
kW
Type of heat output / room temperature control
Single stage heat output, no room temperature control
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
With electronic room temperature control plus day timer
With electronic room temperature control plus week timer
Other control options
Room temperature control, with presence detection
Room temperature control, with open window detection
With distance controle option
No
No
No
Yes
Yes
Yes***
Yes***
Yes***
Yes
Global 70XT BF-01 RCE
Built-in
Closed combustion
C11, C31, C91
I
2EK
, I
2ELL
, I
2H
, I
2E+
, I
2E
, I
2H
I
3P
150/100
DRU LAS ES-E 200/150/100, DRU LAS ES-I 150/100,
DRU LAS AG-I 150/100
Pilot flame with thermocouple
Yes
No
Yes
200 cm
2
* This appliance is suitable for G25.3 with the composition according NTA 8837.
** System efficiency.
*** To be used by means of home automation.
Model identifier(s)
Type of appliance
Combustion
Type
Categorie
Concentric appliance connection
Applicable concentric systems
Flame protection version
2nd thermocouple safety
Atmosphere safety
Explosion hatch
Ventilation hole chimney breast
Table 2: Technical data
Summary of Contents for 70XT BF
Page 31: ...E n g l i s h INSTALLATION MANUAL 31 U T S 38c 2577 0 R L G H M 38c 2578 0 7 6...
Page 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0806 0 A B C D E F G H A B 38P 0807 0 C 14 13...
Page 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0808 0 F D 38P 0809 0 E 16 15...
Page 37: ...E n g l i s h INSTALLATION MANUAL 37...
Page 38: ...E n g l i s h INSTALLATION MANUAL 38...