![Global American 3304030 User Manual Download Page 21](http://html1.mh-extra.com/html/global-american/3304030/3304030_user-manual_2232657021.webp)
3304030 User’s Manual Hardware Setup
2.6 <Watchdog Timer Setting>
The watchdog timer makes the system auto-reset while it stops to work for a period. The
integrated watchdog timer can be setup as system reset mode by program.
Timeout Value Range
- 1 to 255
- Second or Minute
Program Sample
Watchdog timer setup as system reset with 5 second of timeout
2E, 87
2E, 87
2E, 07
2F,
08
Logical
Device
8
2E,
30
Activate
2F, 01
2E,
F5
Set
as
Second*
2F, 00
2E,
F6
Set
as
5
2F, 05
* Minute: bit 3 = 0; Second: bit 3 = 1
You can select Timer setting in the BIOS, after setting the time options, the system will
reset according to the period of your selection.
For more specification of watchdog timer program, please check appendix document.
Watchdog Timer Setting