3301825 3.5” Embedded SBC
The COM 2 Function Select jumper sets the communication protocol used by the second
serial communications port (COM 2) as RS-232, RS-422 or RS-485. The COM 2 Function
Select settings are shown in
Table 5-7
.
COM 2 Function Select
Description
Short 1-2
RS-232
Default
Short 2-3
RS-422
Short 3-4
RS-422
Short 4-5
RS-485
Table 5-5: COM 2 Function Select Jumper Settings
The COM 2 Function Select jumper location is shown in
Figure 5-8
.
Figure 5-6: COM 2 Function Select Jumper Location