7

105564

OWNER’S MANUAL

For convenience and efficiency, install heater

• where there is easy access for operation,

inspection, and service

• in coldest part of room

Figure 4 - Mounting Clearances As Viewed
From Front of Heater

36"

2"

FLOOR

CEILING

Minimum

Minimum to Top 
of Carpeting, Tile,
or Other Combustible 
Material

6"

Minimum
From
Sides of
Heater

Left
Side

Right
Side

INSTALLATION

 WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

CHECK GAS TYPE

Use only natural gas. If your gas supply is
not natural, do not install heater. Call dealer
where you bought heater for proper type
heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below:

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

*  An CSA/AGA design-certified equipment
shutoff valve with 1/8" NPT tap is an accept-
able alternative to test gauge connection.
The optional CSA/AGA design-certified
equipment shutoff valve can be purchased
from your dealer. See Accessory, page 18.

LOCATING HEATER

This heater is designed to be mounted on a wall.

 

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and
joining wall.

 WARNING: Never install the

heater
• in a bathroom (Models FA-

10BA and FAS-10BB only. FA-
60BA is allowed in bathroom.
Check local codes.)

• in a recreational vehicle
• where curtains, furniture, cloth-

ing, or other flammable objects
are less than 36 inches from the
front, top, or sides of the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

 CAUTION: If you install the

heater in a home garage
• heater pilot and burner must be

at least 18 inches above floor

• locate heater where moving ve-

hicle will not hit it

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

IMPORTANT: 

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Fresh Air for Com-
bustion and Ventilation, 
pages 4 through 6.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source.  If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use  this heater
as your primary heating source.

Continued

INSTALLING HEATER TO WALL

Mounting Bracket

The mounting bracket is located on back
panel of heater. It has been taped there for
shipping. Remove mounting bracket from
back panel.

Mounting
Bracket

Figure 5 - Mounting Bracket

INSTALLING THERMOSTAT
SENSING BULB -

For T-Stat Models Only

Remove clip and bulb from shipping loca-
tion. Place clip and bulb into operation loca-
tion (see Figure 6)

Figure 6 - Moving Thermostat Sensing
Bulb

Summary of Contents for FA-10BA

Page 1: ...ationandservicemustbeperformedby a qualified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions f...

Page 2: ...in the same room with heater Make sure grill guard is in place before running heater Keeptheapplianceareaclearand free from combustible materials gasoline and other flammable vapors and liquids 1 Thi...

Page 3: ...on 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY...

Page 4: ...ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to th...

Page 5: ...all fuel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas fir...

Page 6: ...hepowervent VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent...

Page 7: ...ssthan36inchesfromthe front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas CAUTION If you install the heater in a home garage heaterpilotandburnermustb...

Page 8: ...s or to solid walls concrete or masonry Decidewhichmethodbettersuitsyourneeds Eithermethodwillprovideasecureholdfor the mounting bracket Removing Front Panel Of Heater 1 Remove two screws near bottom...

Page 9: ...erconnectheater to private non utility gas wells This gas is commonly known as well head gas CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas...

Page 10: ...supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Pressurize supply piping system by ei ther using com...

Page 11: ...e to the PILOT IGN position MANUAL LIGHTING PROCEDURE OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow th...

Page 12: ...st time after hook ing up to gas supply If so you may need to press in control knob for 30 seconds This will allow air to bleed from the gas system 6 Release downward pressure on con trol knob and tur...

Page 13: ...r thermostat model see Troubleshooting pages 14 through 16 GRH OV 007 GOOD PILOT LP MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Light ing Instructions page 12 2 With control knob presse...

Page 14: ...ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released R...

Page 15: ...hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum inst...

Page 16: ...Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 13 1 Locate and correct all leaks see Check ing Gas Connections page 10 2 Replace control valve 1 Take apart gas...

Page 17: ...address listed on the back page of this manual Send a check for 5 00 payable to DESA International You may have further questions about in stallation operation or troubleshooting If so contact DESA I...

Page 18: ...date Usually we will ask you to return the defec tive part to the factory REPLACEMENT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchase this heater accessory...

Page 19: ...y W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater Fireplace Store...

Page 20: ...105564 NATURAL GAS HEATER FA 10BA 28 2 28 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 32 2 3 19 17 8 9 22 32 31 26 30 27 23 18 28 29 10 21 20 18 30 25 24 22 17 16 13 1 14 15 7 11 12 33 4 5 7 6 7...

Page 21: ...r 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line Assembly 1 19 L98127 02 Lower Gas Outlet Tube Assembly 1 20 L98...

Page 22: ...22 105564 NATURAL GAS HEATER FA 60BA 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 29 2 3 19 17 8 9 29 28 23 27 24 20 18 25 26 10 18 9 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7...

Page 23: ...trol Knob 1 13 L98029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line...

Page 24: ...24 105564 NATURAL GAS HEATER FAS 10BB 27 2 27 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 14 2 3 20 19 14 12 25 8 11 11 13 10 26 22 20 27 28 13 10 24 23 21 19 21 15 1 16 17 7 18 4 5 7 6 7 7 9...

Page 25: ...Screws 2 12 L98010 08 Grill 1 13 L98411 01 Ignitor Line 1 14 L98011 01 Grill Fastener 2 15 L99029 07 Pressure Regulator 1 16 L98801 01 Washer 2 17 L98806 01 Self Tapping Screw 2 18 L98085 02 Mounting...

Page 26: ...unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maint...

Reviews: