24
09/20/18
After modifying the km/mile setting, short press SW once to complete the NORMAL
SETTING. The speed and distance flashing should stop. If user needs to get back to the
OPERATING mode at this time, simply long press SW. If user needs to get into P mode in
the SETTING, press and hold the Up and Down at the same time. P1 will start to flash
at the bottom of the screen.
P Mode Values:
All the P mode values are pre-determined by factory and should NEVER be changed by
user. In case user inadvertently modified factory default value, below chart provides a reference
for user to reset to the factory default value. User needs to toggle through P value by short
pressing SW. Please do not press Up or Down while going through P mode.
Setting Description
Factory Default
P 1
Number of motor magnet steel
30
P 2
Rotation pulse
0
P 3
Power Assist Mode
0
P 4
Acceleration Start Mode
0
P 5
Battery level monitoring
12
C Mode Values
In order to get into C mode value settings, user must toggle through P mode by short
pressing SW. At the end of P5 setting, short press SW so that P5 value is no longer flashing. Then
long press Up and Down at the same time to get into C mode. C1 will start flashing at the bottom
of the screen. Most of the values in C mode are pre-determined by factory and should NEVER be
changed. Below chart provides a factory default in case some values are inadvertently modified by
user.
Setting
Description
Factory Default Value
C1
Power Assist Sensor Mode (Do not change)
02 /10
C2
Motor Sensor Type (Do not change)
0
C3
Gear Level Default (When turning on scooter, which
gear is the default)
1 (Strongly
recommend as gear 2
or 3 is fast and could
cause accidents if not
used appropriately)
C4
Acceleration Setting (See details below)
4/33
C5
Controller Maximum Electric Current Level (Do not
change)
00
C6
Display Brightness Setting (1-5)
3
C7
Cruise Control Setting (Disabled)
0
C8
Motor Temperature Monitoring (Disabled)
0
C9
Password Locking Control (See details below)
0
C10
Master Reset (Do not change)
n
C11
Display Protocol (Do not change)
0
C12
Controller Minimum Voltage (Do not change)
4
C13
Electric Braking Strength Level (1-5 See below)
5
C14
Power Assist Micro Configuration (Do not change)
2