66
A
C
FIG. 3 • Hose
Connections
D
E
1. Remove top screw from hole.
2. Place screw through top hole
on air fi lter bracket. Tighten
screw. Lower screw keeps
fi lter from swinging freely; do
not tighten or remove.
3. Power off system and air
supply. Connect supplied
short black hose (#044-229)
to straight fi tting on fi lter.
Connect other end to “Air
Input” fi tting.
To mount elsewhere, use
supplied longer black hose
(#044-069) — see page 18.
4. Connect hose from air supply
to fi lter fi tting marked “N
”.
FIG. 2 • Mounting Air Filter to Side
7
9
6
10
8
11
1
3
4
Air Filter
Knob
Drain water from fi lter
daily. Turn knob clockwise
(from top view) to open.
Drain. Turn knob counter-
clockwise to close valve.
A
A
Turn Clockwise
2
NOTE: If air supply
hose is larger than
1/4" (6.35 mm) OD,
either replace the
push-to-connect
fi tting with the
included barbed
fi tting and attach the
air supply hose or
purchase a reducer
to decrease the OD
to 1/4" (6.35 mm).
A. Standard Handpiece fi tting
B. Air fi lter fi ttings
C. Foot Throttle fi tting
D. 24-V power converter receptacle
E. 24-V power converter (#022-987)
B.2
B.1