Installing Your Cooker
36
Connecting to the gas supply
Means of isolation shall be provided at the shut off point by
either an approved quick connect device or a Type 1 man-
ual shut off valve. The outlet of the quick connect device
shall be at, or below, the horizontal position.
Connection to the gas supply should be made using the
Aquaknect AS/NZS 1869 class B hose assembly with an
internal diameter of not less than 10mm (supplied with the
appliance) and regulator (regulator for use with natural
gas)
NOTE: Maximum length of hose 900mm.
The temperature rise of the areas at the rear of the cooker
that are likely to come into contact with the flexible hose do
not exceed 70˙C.
Ventilation requirements
Ventilation must be as specified by AS5601 Installation code.
The room containing the appliance should have an air sup-
ply.
An appliance should be installed in a location for complete
combustion of gas, proper flueing and to maintain ambient
temperature of the immediate surrounding at safe limits,
under normal conditions.
LP Gas only -
Do not install this appliance in a room below
ground level. This does not preclude installation into rooms
which are basements with respect to one side of the build-
ing, but open to ground level on the opposite side.
Failure to install appliances correctly is dangerous and could
lead to prosecution.
After installation make sure all connections are gas
sound.
Commissioning
Pressure settings:
Natural Gas - 1.0 kPa
Butane - 2.75 kPa
Propane - 2.75 kPa
Hob
Turn on gas supply and check for soundness at the hot-
plate injector. Light two burners and check that the pres-
sure is correct.