www.glendimplex.de

452237.66.61 · FD 0001

EN-2

PSP 300U 

English

2

Positioning

2.1 General

Mounting and installation must be performed by a qualified
specialist company. The unit must be installed in a room pro-
tected from frost with short pipe runs.

ATTENTION!

!!

Risk of injury due to improper installation.
Sharp-edged components, points and corners can cause
injuries.

Ensure that the installation location for cleanliness before
starting work.

Ensure there is sufficient space for installation.

Handle exposed sharp-edged components with care.

Install components correctly. Note the high net weight of
some components. If required, use lifting gear.

Where necessary secure components to prevent them fall-
ing or tipping over

The operating overpressures indicated on the type plate must
not be exceeded.
The buffer tank is only designed to withstand strain from a
specified, evenly applied heat pump (see device information,
maximum load). Other forms of strain, particularly when limited
to individual points, are not permitted. The connection cable
can be laid in the bottom section.

NOTE

º

The buffer tank is not enamelled and, for this reason, should
never be used for domestic water heating.

All connections lead out through the insulation. If a connecting
stub is not in use, it should be sealed with a cap or sealing plug.
A means of draining the tank should be fitted at the lower stub.

2.2 Immersion heater connection

If the buffer tank is fitted with an immersion heater, it must be
connected using a type-tested diaphragm safety valve which
cannot be shut off. The connection diameter must have a nom-
inal width of at least 20. The air outlet pipe must not allow any
pressure increase to take place.
Immersion heaters may only be connected by qualified electri-
cians in accordance with the corresponding circuit diagram. All
relevant requirements of the utility company, the Association of
German Engineers (VDE) and DIN 4751-2 regulations must be
observed.

3

Commissioning

Ensure that the water supply is turned on and the buffer tank is
filled before commissioning.
The entire system, including all factory installed components,
must be inspected to ensure that everything is working prop-
erly and that they are leak tight.
The operational reliability of the safety valve must be checked
at regular intervals.

4

Removal and disposal

4.1 Safety notes 

ATTENTION!

!!

Risk of injury due to improper removal.

Stored electrical or heat energy, sharp-edged components,
points and corners can cause injuries.

Ensure sufficient space for removal before starting work.

Handle exposed sharp-edged components with care.

Ensure the work area is tidy and clean. Components lying
loose on top of one another or around the device are po-
tential sources of accidents.

Remove components correctly. Note the high net weight
of some components. If required, use lifting gear.

Secure components to prevent them falling or tipping over

4.2 Disposal

NOTE

º

Pay attention to environmental protection and the risks to the
environment of incorrect disposal. 

Dispose of materials and components properly and in an envi-
ronmentally sound manner through an authorised disposal site.
Comply with all local regulations.

Engage approved specialist companies for disposal of
electrical waste, electronic components, lubricants and
other operating materials.

In case of doubt, obtain information on environmentally
sound disposal from the local authority or specialist dis-
posal companies.

If no take back or disposal agreement is in place, send disman-
tled components for recycling:

Scrap all metals.

Send plastic items for recycling.

Dispose of other components sorted by material proper-
ties.

Summary of Contents for PSP 300U

Page 1: ...und Gebrauchsanweisung Unterstell Pufferspeicher 300 Liter f r W rmepumpen Installation and Operating Instruction 300 litre built under buffer tank for heat pumps Instuctionsd installation et d utilis...

Page 2: ......

Page 3: ...hrleistung und Haftung DE 2 1 3 Bestimmungsgem er Gebrauch DE 2 1 4 Sicherheitsma nahmen DE 2 1 5 Elektrischer Anschluss DE 2 2 Aufstellung DE 3 2 1 Allgemein DE 3 2 2 Anschluss Tauchheizk rper DE 3 3...

Page 4: ...auf eine oder mehrere der folgenden Ursachen zur ckzuf hren sind Nicht bestimmungsgem e Verwendung Nichtbeachten der Anleitung Betrieb mit nicht funktionsf higen Sicherheits oder Schutzeinrichtungen...

Page 5: ...eizk rper sind nur von zugelassenen Elektroinstallateu ren nach dem entsprechenden Schaltbild anzuschlie en Die Vorschriften des EVU VDE und DIN 4751 2 sind zwingend zu beachten 3 Inbetriebnahme Vor I...

Page 6: ...keit kg 400 2 5 Ger teanschl sse Heizstabeins tze Zoll G 1 IG Heizwasservorlauf Zoll G 1 AG Heizwasserr cklauf Zoll G 1 AG 3 Sonstige Ausf hrungsmerkmale 3 1 zul Betriebstemperatur Heizwasser C 95 3 2...

Page 7: ...tion EN 1 1 2 Warranty and Liability EN 1 1 3 Intended use EN 1 1 4 Safety measures EN 1 1 5 Electrical connection EN 1 2 Positioning EN 2 2 1 General EN 2 2 2 Immersion heater connection EN 2 3 Commi...

Page 8: ...accepted if they can be attributed to one or more of the following causes Unintended use Failure to observe instructions Operation with defective safety or protection equipment Continuing use despite...

Page 9: ...y be connected by qualified electri cians in accordance with the corresponding circuit diagram All relevant requirements of the utility company the Association of German Engineers VDE and DIN 4751 2 r...

Page 10: ...ice connections Heating element inserts inches G 1 IG Heating water flow inches G 1 AG Heating water return inches G 1 AG 3 Additional model features 3 1 Permissible operating temperature heating wate...

Page 11: ...sponsabilit FR 1 1 3 Utilisation conforme FR 1 1 4 Mesures de s curit FR 1 1 5 Branchements lectriques FR 1 2 Installation FR 2 2 1 G n ralit s FR 2 2 2 Raccordement de la r sistance immerg e FR 2 3 M...

Page 12: ...l une ou plusieurs des causes suivantes Utilisation non conforme Non respect des pr sentes instructions Utilisation avec des dispositifs de s curit et de protection inop rants Poursuite de l utilisat...

Page 13: ...est autoris raccorder des r sistances immerg es conform ment au sch ma de c blage correspondant Les prescriptions de la so ci t d lectricit ainsi que les prescriptions VDE et DIN 4751 2 doivent tre i...

Page 14: ...ts de l appareil Inserts de r sistance lectrique Pouces G 1 IG D part d eau de chauffage Pouces G 1 AG Retour d eau de chauffage Pouces G 1 AG 3 Autres caract ristiques techniques 3 1 Temp rature de f...

Page 15: ...www glendimplex de 452237 66 61 FD 0001 FR 4 PSP 300U Fran ais...

Page 16: ...hland GmbH Gesch ftsbereich GDTS Am Goldenen Feld 18 D 95326 Kulmbach Irrt mer und nderungen vorbehalten Subject to alterations and errors Sous r serve d erreurs et modifications 49 0 9221 709 924545...

Reviews: