7
in the most appropriate place for
securing and using the provided
L-bracket and the screw that was
removed attach the firebox to the
mantel. (Figure 2)
!
NOTE:
There are no guide
holes provided for the L-Brackets
in the mantel.
Custom Installation
1. Mark the desired location on
the floor and store the fireplace
in a safe, dry and dust free
location.
2. Frame an opening of 27.0 in.
(686 mm) wide x 23 ⅜ in. (593
mm) high x 7 ½ in. (191 mm)
deep (Figure 3).
Option #1
- The power cord can
be lead from behind the trim and
along the wall to an outlet near
the fireplace.
Option #2
- A new outlet can be
installed inside the new frame
construction. Plug the unit directly
into a 15 A, 120 V outlet.
!
NOTE:
A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not
essential in all cases. A dedicated
circuit will be required if, after
installation, the circuit breaker
trips or fuse blows on a regular
basis when the heater is operating.
Fireplace Installation
Figure 2
Additional appliances on the same
circuit may exceed the current
rating of the circuit breaker.
3. Install the provided plastic feet
to the unit as shown in Figure 4.
CAUTION:
Clearance for
air circulation beneath the
fireplace insert is provided by
feet.
C
B
A
Figure 3
27.0 in.
(686 mm)
7 ½ in.
(191 mm)