![gledhill GC2000/120/E Design, Installation & Servicing Instructions Download Page 28](http://html.mh-extra.com/html/gledhill/gc2000-120-e/gc2000-120-e_design-installation-and-servicing-instructions_2231189028.webp)
Supplied By www.heating spares.co Tel. 0161 620 6677
Page 28
Page 29
GULFSTREAM
2000
User’s Instructions are provided on the front of this appliance and also a separate
user booklet is also packed with the appliance.
Your GulfStream 2000 has been designed to operate at its most efficient when
left ON DEMAND at all times.
The time clock and room thermostat, as in a traditional system, controls the
central heating.
LIGHTING INSTRUCTIONS
1. Turn on the gas and electrical supplies to the appliance.
2. Ensure the appliance is switched ON.
3. Ensure all external controls are set to the ON position.
LIGHTING SEQUENCE
1. The appliance fan will start.
2. After a short period the ignition sparking will commence.
3. The main burner will light.
4. Indication of the appliance status is shown on the facia panel.
HEATING/HOT WATER FAILURE
If the boiler does not fire and the heating and/or hot water is lost first check:
1. That the room thermostat is set high enough.
2. That the time clock is in an ON period.
3. That power is being provided - indicated by the green ‘ON’ light, and that
the gas supply is available.
4. That the primary water pressure is between 1 and 2 bars.
5. That the automatic air vent on the top of the appliance is not screwed down.
6. That the ignition reset button (ignition lockout indicator light on) does
not require resetting.
7. That the boiler overheat reset button does not require resetting (under black
cap).
IF EITHER RESET BUTTON REQUIRES RESETTING, PRESS IN ONCE OR TWICE. IF THE
APPLIANCE DOES NOT UNLOCK WAIT 15 SECONDS AND TRY AGAIN. IN CERTAIN
CIRCUMSTANCES LOCK OUTS MAY OCCUR, IT IS ONLY NECESSARY TO CALL AN
ENGINEER IF THIS HAPPENS ON A REGULAR BASIS.
EMERGENCY SHUTDOWN
1. Turn off the electrical supply to the appliance at the fused isolator switch.
2. Turn off the gas to the appliance at the gas meter.
CLOCK INSTRUCTIONS
The clock can be set as follows:
COARSE ADJUSTMENT: Rotate the outer (24hr) dial clockwise until the stationary
marker arrow is almost opposite the current time.
FINE ADJUSTMENT: Rotate the minute hand in a clockwise direction to accurate
time.
TO SELECT THE ‘ON’ PERIOD(S) REQUIRED: Push the appropriate tappets surrounding
the 24 hr dial to their outer position.
MANUAL OVERIDE (located between 3 & 4 p.m.,
on the inner dial)
Upper position: permanently ‘ON’
Centre position: time controlled ‘ON’ and ‘OFF’
Lower position: permanently ‘OFF’
Hot water is not time controlled and is available
at all times.
SWITCH
This unit is fitted with ‘Switch’ which provides
an emergency electric back-up system, for
heating and hot water in the heating season or
hot water only in the summer. It should only
be left in this mode until a service engineer is
called since there is no temperature control
to the domestic hot water and care should
be taken when putting hands directly under
taps.
TO ACTIVATE, SWITCH TO POSITION 1 FOR HOT
WATER AND 2 FOR HEATING AND HOT WATER,
THEN CALL A SERVICE ENGINEER.
USER INSTRUCTIONS
Summary of Contents for GC2000/120/E
Page 30: ...Supplied By www heating spares co Tel 0161 620 6677 Page 30 FAULT FINDING ...
Page 31: ...Supplied By www heating spares co Tel 0161 620 6677 Page 31 GULFSTREAM 2000 FAULT FINDING ...
Page 35: ...Supplied By www heating spares co Tel 0161 620 6677 Page 35 GULFSTREAM 2000 FAULT FINDING ...
Page 36: ...Supplied By www heating spares co Tel 0161 620 6677 Page 36 FAULT FINDING ...
Page 37: ...Supplied By www heating spares co Tel 0161 620 6677 Page 37 GULFSTREAM 2000 FAULT FINDING ...
Page 50: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 51: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 52: ...Supplied By www heating spares co Tel 0161 620 6677 ...