GlassOuse User Manual
4
GlassOuse Assistive Device
Mobile (Android, Windows)
4.
Sleep mode
To extend battery life and not disturb you while you are watching films or listening to
music, GlassOuse enter “Sleep” mode if the “Click” is not pressed for 3 minutes.
5.
Reset to Factory Settings
If GlassOuse does not respond properly, the battery indicator does not work accurately,
or you encounter a similar problem, you can press “Reset” to return the device to
factory settings. Pressing it for 1 second is enough.
6.
Calibration
If the cursor moves abnormally (e.g. vibration, sliding), calibration is recommended.
Calibration is also advisable before first use. It should take a maximum of three
minutes to complete the entire process. To calibrate GlassOuse:
a.
Make the Bluetooth connection with your tablet. Press the “Reset” button.
b.
Put GlassOuse on a flat, steady table. The“Click” cable should be in a
suspended position.
c.
During calibration, the LED will alternate between blue and red for about 1
second at a time. When the red colour is sustained, the calibration is
completed, and you can start using the device.