background image

12

Glass Shelves Installation

After the Mirrored Cabinet box has been properly in-
stalled, determine the appropriate height and location for
the glass shelves.
Note: make sure the back wall mirror has been 
completely cleaned after installation.  If cleaning the back
wall mirror is necessary, use a household non-ammonia
glass cleaner.

Cleaning Recommendations: 

Never use abrasive cleaners or cleaners containing
ammonia. This may cause chemical damage to the
mirror and void the warranty.

Besides the factory installed Electric Option shelf assembly,
the cabinets come with the following:

30” Height Series = 3 Glass S 12 Shelf Clips

36” Height Series = 4 Glass S 16 Shelf Clips

For cleaning the mirror, we recommend using
“ammonia free” sprayway brand glass cleaner,
which is available at a variety of retail outlets.
www.spraywayinc.com/content/glass-cleaner

each glass shelf will require four (4) shelf clips.
Use care when handling the non-tempered
glass shelves. on a level plane insert the shelf
clips into the pre-punched holes. The clips are
designed for a tight tension fit to hold the shelf.
Place each glass shelf on the top of the left clip
first, then slowly lower onto the right clip with a snap fit.

After glass shelves are installed insert hole plugs in all
open holes to complete installation.

Maximum load for 5/16” Clear Glass Shelf is 3 pounds.
Maximum load for Aluminum Electrical Shelf is 3 pounds.

Hole Plugs

5/16” Clear Glass shelf

White opal Acrylic shelf

electrical shelf

Summary of Contents for GC1630

Page 1: ...tric wiring must be by a licensed electrician Recessed or wall mounted installations to be performed by a professional installer See pages 7 through 10 of this manual This unit s electrical connection...

Page 2: ...r 14 15 Warranty 16 Unpack all parts carefully and protect Glass and Mirror parts during installation Carefully review all parts and read the installation instruction before you start Please refer to...

Page 3: ...own open without the door for Electric Option details Defogger connector Defogger outlets Outlet 110V Outlet 110V Defogger Switch Blue Light LED Light Switch White Light Electric Shelf 2 7 8 deep for...

Page 4: ...ee page 6 For Recessed Left or Right side access as determined at the time of order by the door hand For Surface Mount rear access See page 9 NOTE Only remove the Electric Option shelf s front cover t...

Page 5: ...Circuit Interrupter when used in bathrooms and all other locations required by the National Electric Code NOTES This Electric Option shelf has been factory in stalled Do not alter change or add any wi...

Page 6: ...cabinet height less 5 8 R O Height RECESSED MOUNTING Rough Opening Note Cabinet installs over nished wall with sheetrock and or tile nishes com pleted 3 4 Flange on all sides of the cabinet will cover...

Page 7: ...n in stalling this cabinet over the nished surface that includes tile the location of the wire access hole must be repositioned to allow for the thickness of the sheetrock and the tile B Cabinet can b...

Page 8: ...ly assembled refer to R o formula chart on page 7 to determine the R o required for the unit as assembled Assembling multiple cabinet units 1 Place the units on a 2x4 or 2x6 stud of sufficient horizon...

Page 9: ...Mounting to wall Refer to pages 3 6 and to Steps 1 5 on page 5 for detailed diagrams Open front panel in Electric Option shelf using the Allen wrench supplied Do not lose the Allen screws provided Ti...

Page 10: ...iagram EL1 for the access points 110v outlets LED Light Heated Door Defogger switch blue Integral LED Light Switch white 6 White Opal Acrylic shelf is packed separately and must be placed in position...

Page 11: ...essed Mirrored Cabinets 1 Attach the side mirror kit brackets thru the pre punched holes in your cabinet 2 Try to use the rst row of holes from the top and bottom of your cabinet Using the eight 10 32...

Page 12: ...t Series 4 Glass Shelves 16 Shelf Clips For cleaning the mirror we recommend using ammonia free sprayway brand glass cleaner which is available at a variety of retail outlets www spraywayinc com conte...

Page 13: ...ove the door from the carton Hold the door in the upright po sition snap open the factory installed hinges Place the hinge onto the factory installed mount ing plate in the cabinet Toe rst and snap in...

Page 14: ...Hole Plugs 40 433 00 40 433 00 Cabinet Connectors 4 Cabinet 2 426 00 4 426 00 Cabinet Connectors 6 Cabinet 2 429 00 4 429 00 Cabinet Connector Mounting Screws 8 18 855 10 32 x 1 2 8 18 855 10 32 x 1...

Page 15: ...4 Model GC 2436 4 Model GC 2430 6 Model GC 2436 6 Qty Part Number Qty Cabinet 4 Cabinet Electric Option 1 GC2430 4 Cab E R or L 1 GC2436 4 Cab E R or L Cabinet 6 Cabinet Electric Option 1 GC2430 6 Ca...

Page 16: ...and soft closing cushions have a separate lifetime warranty from Blum Inc This warranty is against defects in materials and workmanship as long as the original consumer owns the product This is a warr...

Reviews: