background image

Cables

Mains supply cable must be approved for fixed installation. The external diameter can be 4–12 mm (M20 gland) or 

10–18 mm (M25 gland) as main choice, but different glands sizes can be supplied. Cross sectional area of the wires 

can be between 1.5 and 6.0 mm

2

. The cable must have an earth wire and shielded cable is recommended to be 

used.

Operation of MAX LED in emergency mode

MAX 600 LED 2200 give 16% light level at E1 and 9% at E3. MAX 1200 LED 4500 give 13% light 

level at E1 and 6% at E3. When mains voltage is switched on the charging indicator (green LED) will light, indicating 

charging of the battery. If the connection to the battery is disrupted or the battery is defect, the indicator will not light. 

Reset fault indication by switching off/on power supply. A new or discharged battery must be charged for at least 24 

hours in order to be full charged.

Battery pack replacement

When the battery pack is defect or need to be replaced, use only original battery pack from Glamox 

•  4.8V 4.0Ah Item no: PA140818001 for MAX 600/1200 LED 3500/6500

•  7.2V 4.0Ah Item no: PM161012000 for MAX 600/1200 LED 2200/4500

Battery type is marked inside MAX LED.

Do not replace the battery when an explosive atmosphere is present.

Control and inspection

General inspection and main function control to be carried out once a month. Fully emergency duration test by 

switching off power supply should be performed at least once a year and the specified emergency light time shall be 

observed.

Maintenance

The MAX LED is designed to operate many years with a minimum need for maintenance. However it may be 

necessary to clean the diffuser if it gets dirty. Do never use any solvents for cleaning polycarbonate diffuser due to risk 

of generating static charge. Use moist cloth only, no solvent. If battery and other components need to be replaced, it 

is important to use only original Glamox components.

Cycling of battery

To have best lifetime of batteries, cycle the batteries at least 2 times by charging for 24 h and discharge until the 

emergency light turns off. To cycle, just switch the circuit breaker on/off.

MAX LED operation, inspection and maintenance

8

Summary of Contents for MAX LED Series

Page 1: ...Glamox MAX LED User manual ...

Page 2: ...d maintenance manual zusammen mit ihrem Produkt auf unsere Webseite Suomi Tarkemmat asennus ja huolto ohjeet löytyvät tuotteen mukana toimitetusta ohjeesta sekä internetsivuiltamme Eesti Lisainformatsiooni saamiseks vaata palun Installation and maintenance manual mis on kaasas valgustiga ning leitav ka meie koduleheküljelt Nederlands Voor verdere installatie en onderhoud zie het document Installat...

Page 3: ...Dit kan de elektronica beschadigen Dansk Tilslut ikke armaturet til midlertidig byggestrøm Dette kan skade elektronikken Polski Nie podłączać do tymczasowego źródła zasilania Może to uszkodzić elektronikę Deutsch Die enthaltene Lichtquelle in dieser Leuchte darf nur durch den Hersteller seinen Kundendienst oder eine ähnlich qualifizierte Person ersetzt werden Stromführende Teile im Innern GEFAHR E...

Page 4: ...e voltage 110 254V AC 50 60Hz and 220 250VDC Supplied current mains mode 0 11 0 56A Power factor 0 92 0 96 Light modules LED For more information please see www glamox com 0470 Types L1 C1 L C Hood nuts M8 distance MAX 600 LED 724 704 687 400 430 500 MAX 1200 LED 1334 1314 1296 500 700 950 X Special conditions for safe use Potential electrostatic charging hazard For cleaning use moist cloth only N...

Page 5: ...Installation and operation MAX LED Terminal block Torque value for screws 1 8Nm Type and size of wires that can be used Solid wire From 1 0mm to 6 0mm Stranded wire with or without ferrule From 0 75mm to 6 0mm There can only be connected one wire on each side of the screw on each side of each terminal totally max 4 wires at each terminal Earthing the luminaire The luminaire must be earthed in the ...

Page 6: ... MAX HF Not emergency MAX HF E Emergency Wiring with 2 poled switch for main light M20 M25 Polyamid 5 0 Nm 8 13mm 7 5 Nm 12 18 mm Torque Cabel diameter Brass 7 5 Nm 4 12mm 10 0 Nm 12 18mm Torque Cabel diameter MAX LED E MAX LED MAX LED E 6 Installation and operation ...

Page 7: ...85 mm 7 MAX LED mounting 1 2 3 4 With plastic folio at diffuser 5 6 7 8 9 10 11 12 Remove plastic folio before powering 1 8 Nm ...

Page 8: ...ck from Glamox 4 8V 4 0Ah Item no PA140818001 for MAX 600 1200 LED 3500 6500 7 2V 4 0Ah Item no PM161012000 for MAX 600 1200 LED 2200 4500 Battery type is marked inside MAX LED Do not replace the battery when an explosive atmosphere is present Control and inspection General inspection and main function control to be carried out once a month Fully emergency duration test by switching off power supp...

Page 9: ...9 Battery change Battery pack Spareparts item no PA140818001 4 8V 4 0Ah PM161012000 7 2V 4 0Ah 1 2 Nm ...

Page 10: ...10 ...

Page 11: ...ging Open the luminaire and check the following The connection of L4 N the battery and the charging unit Check if battery is connected and OK The HFXE LED or battery might be defect Emergency illuminance level is too low Clean the cover of the luminaire Change the battery Emergency lighting time is under the specified time 1 5 or 3 0 hours for standard luminaire Change the battery Manufacturer Gla...

Page 12: ...Please visit our web site for contact information www glamox com Please refer to our website for information about our 5 year warranty Glamox August 2020 Item no 72596948 ...

Reviews: