15
LED Status
Power-off/Standby/Hibernate
Discharging
LED status is off
Charging state
When AC adapter is plug in
Blinking red status signify it starts charging.
Adapter is plugged in the system.
Capacity <30% -
LED blinking in red color (interval of 2 sec/cycle)
30%
≤ capacity < 100% -
LED lit in red color
If over temperature, LED cycles (0.6s/cycle): blue (0.3s) ->off (0.3s)
->Red (0.3s) ->off (0.3s) ->blue
Battery fully charged / 100% -
LED lit in blue color
At the time of plugging-in AC adaptor, if battery capacity was above
95% (>95%), the battery will stop charging.
Power-On Status
Discharging
30
% ≤ capacity
LED status is off
10% ≤ capacity < 30%
LED status is off
5%
≤ capacity < 10%
LED status is off
Beeps 3 times in 1.2 sec (each beep lasts for 200ms then 200ms off
interval before the next beep
0 < capacity < 5%
LED status is off
Beeps 3 times in 1.2 sec (each beep lasts for 200ms then 200ms off
interval before the next beep
Charging state