9 HOMEDEPOT.COM/GLACIERBAY
Operation (continued)
3
2
1
CAUTION:
Use caution when removing the quick
connecting hose connections in order to prevent cutting
your hands.
□
If it is necessary to remove the quick
connector, push the quick connector
housing (J) up, hold the housing together
and pull down.
Problem
Possible Cause
Solution
There are leaks from the handle.
The bonnet nut is loose.
The O-ring on the cartridge is
dirty or damaged.
□
Tighten the bonnet nut.
□
Clean or replace the O-ring.
The aerator is dirty or mis-fitted.
The cartridge may be clogged.
□
Remove the aerator and check for
debris.
□
Remove cartridge and check for
debris.
Ensure the aerator is properly
installed.
The spout leaks.
The retainer nut is loose.
□
Tighten the retainer nut.
The sink drain at the base of the
sink is leaking.
The sink surface is rough or
irregular.
□
Apply additional silicone sealant to
the beveled side of the drain flange.
□
Apply silicone sealant to the beveled
side of the rubber washer on the
drain body.
□
Retighten and test for leaks.
The locking nut is loose or
cartridge is not positioned
correctly.
□
Remove the cartridge to check the
rubber seat and spring.
□
Tighten lock nut.
□
Clean or replace.
The aerator leaks or has a reduced
water flow.
The water will not shut off
completely.
Care and Cleaning
To clean, wipe down with a damp cloth and towel dry.
Do not use abrasive cleaners, steel wool, or harsh chemicals when cleaning this faucet, or the warranty will
be voided.
Troubleshooting
2
Removing the quick connector
NOTE:
Refer to the service parts section in this manual for
a detailed drawing showing the location of the parts listed