Glacier bay 1003421140 Installation And Care Manual Download Page 8

 

 

 

Installation (continued)

Installing the supply 
connections

 

 

Tighten the pipes to the valve body (D) with a 
pipe wrench (not included).  

Wrap thread sealant tape (not included) around 
the pipe threads in a clockwise direction, as 
shown. 

Connect the hot and cold water supply lines (1, 
not included), the shower outlet pipe (2, not 
included), and tub outlet pipe (3, not included) 
by threading them into the valve body (D) in a 
clockwise direction.  

Connect the pipe elbows (4, not included) to 
the end of the shower outlet and tub outlet 
pipes.

 

NOTE: 

The hot water supply lines go into the "H" inlet, and 

the cold water supply lines go into the "C" inlet. Do not use 
PEX or CPVC between the valve body (D) and tub spout (J).

NOTE:

              If you do not wish to install the tub outlet, insert 
the plug (I) into the bottom of the valve body (D). 

4

Back to back installation

NOTE: 

Never install the valve body (D) upside down!

 

If the hot and cold inlets are reversed (hot on 
right and cold on left), remove the screw (1), 
inverter (2), sleeve (3), and bonnet (4) from the 
valve body (D) with reversed supply connections. 
Rotate the cartridge (5) 180°, so H appears on 
the right. Install the cartridge making sure that 
the key is fully engaged with the slot in the 
valve body (D). Slide the bonnet (4) over the 
cartridge (5) and thread them onto the valve 
body (D). Hand tighten securely. Reassemble 
the sleeve (3), inverter (2) and screw (1). If you 
are not making a reverse or back to back 
installation, skip this step and continue with 
the step 5.  

 

Normal 
installation 
(changes 
not required)

   Reverse

installation

Normal installation 

Reverse installation

D

H

Hot

Hot

Cold

Cold

H

1 2

3

4

5

Cold

Hot

3

D

1

2

4

I

D

1

2

4

Summary of Contents for 1003421140

Page 1: ...e Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Glacier Bay Questions problems missing parts Before returning to the store call Glac...

Page 2: ...the valve to the tub spout Tools and Hardware Required 3 Warranty LIMITED LIFETIME WARRANTY Glacier Bay products are manufactured with superior quality standards and workmanship and are backed by our...

Page 3: ...DVANCED INSTALLATION Consult a plumber or professional before installing this product If you are replacing your plumbing valve please review the four common plumbing methods illustrated below COPPER I...

Page 4: ...Flathead screwdriver S I L I C O N E Silicone sealant B IPS Key hole saw Flashlight C PEX COPPER Safety goggles Thread sealant tape Tube cutter Strap wrench Adjustable wrench Measuring tape Thermomet...

Page 5: ...D CPVC COPPER Safety goggles Thread sealant tape Tube cutter Strap wrench Adjustable wrench Measuring tape Thermometer Phillips screwdriver Flathead screwdriver S I L I C O N E Silicone sealant Key h...

Page 6: ...tion Quantity A 1 B Shower arm 1 C Shower head 1 D Valve body 1 E Escutcheon 1 F Handle 1 G Set screw 1 H 2 5mm hex wrench 1 Shower flange I Plug 1 J Tub spout 1 K Screw 2 L Plaster guard 1 M Escutche...

Page 7: ...er to Step 2 for valve access hole dimensions The recommended valve depth to the finished wall is 2 1 2 in min to 3 in max Ensure that the valve body D cover is flush with the finished exterior surfac...

Page 8: ...sh to install the tub outlet insert the plug I into the bottom of the valve body D 4 Back to back installation NOTE Never install the valve body D upside down If the hot and cold inlets are reversed h...

Page 9: ...he handle F on the valve body D inverter and turn the handle F to the full on mixed position Turn on the hot and cold water supply lines and allow the water to flow from the outlets for one minute or...

Page 10: ...of the tub spout outlet 1 not included in a clockwise direction as shown Connect the tub spout outlet pipe the tub spout outlet pipe should project 4 7 16 in from the finished wall to the lower pipe...

Page 11: ...in a clockwise direction NOTE The limiter on the valve can be set to allow partial or full access to hot water by limiting how far the handle can be turned to the hot side of the valve The limiter is...

Page 12: ...just the red limit stop ring 1 in a counterclockwise direction and reinstall the red limit stop ring 1 onto the cartridge assembly 2 B Removing the red limit stop ring Remember the position of the red...

Page 13: ...ecure with the screw 3 Screw the sleeve 4 onto the valve body D NOTE Rotate the cartridge stem 1 clockwise to turn off the water before you install the handle 11 Installing the escutcheon and handle I...

Page 14: ...r normally flows through the tub spout J To activate the shower turn the valve on and pull the knob 1 up Hold the knob 1 until the water flows continuously from the shower arm B Check for leaks Shut o...

Page 15: ...om the tub spout is less than 0 01 GPM this is a normal occurrence Or consider the causes below The pipe used between the valve and the tub spout is not 1 2 in IPS or the COPPER pipe is incorrect The...

Page 16: ...on Part Number 10 Screw RP50215 11 Escutcheon RP80656 12 Escutcheon screw RP50066 13 Accessorize cap RP80255 14 Handle assembly RP13656 15 Plug RP70365 16 Spout RP33097 Service Parts Specify Finish Ma...

Page 17: ...ms missing parts Before returning to the store call Glacier Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD GLACIER 1 855 434 5224 HOMEDEPOT COM Retain this manual...

Page 18: ...a completa de productos disponibles para las necesidades de mejoras de tu hogar Gracias por elegir a Glacier Bay GRACIAS Problemas preguntas o piezas faltantes Antes de regresar a la tienda llama al s...

Page 19: ...ca o de la ba era Garant a GARANT A DE POR VIDA LIMITADA Los productos de Glacier Bay est n fabricados con normas y mano de obra de calidad superior y est n respaldados por nuestra garant a de por vid...

Page 20: ...Consulta a un plomero o profesional antes de instalar este producto Si est s cambiando tu v lvula de plomer a consulta los cuatro m todos comunes que aparecen m s abajo COBRE IPS PEX y CPVC Quita la m...

Page 21: ...beza plana S I L I C O N E Sellador de silicona Serrucho de punta Linterna C PEX COBRE Gafas de seguridad Cinta selladora para roscas Cortador de tuber as Llave de correa Llave ajustable Cinta m trica...

Page 22: ...e seguridad Cinta selladora para roscas Cortador de tuber as Llave de correa Llave ajustable Cinta m trica Term metro Destornillador Phillips Destornillador de cabeza plana S I L I C O N E Sellador de...

Page 23: ...Placa protectora 1 F Llave 1 G Tornillo de fijaci n 1 H Llave hexagonal de 2 5 mm 1 Brida de la ducha I Tap n 1 J Ca o de la ba era 1 Pre instalaci n continuaci n CONTENIDO DEL PAQUETE K Tornillo 2 L...

Page 24: ...lta el paso 2 para las dimensiones del orificio de acceso de la v lvula La profundidad recomendada de la v lvula a la pared acabada es de un m nimo de 6 4 cm a un m ximo de 7 6 cm Aseg rate de que la...

Page 25: ...as instalar la salida de la ba era inserta el tap n I en la parte inferior del cuerpo de la v lvula D 4 Instalaci n de parte posterior con posterior NOTA Nunca instales el cuerpo de la v lvula D al re...

Page 26: ...loca la llave F en el invertidor y gira la llave hasta la posici n de mezclado completo Abre las l neas de suministro de agua caliente y fr a y deja que salga el agua durante un minuto o hasta que exp...

Page 27: ...e la ba era 1 no incluido en direcci n de las manillas del reloj tal como muestra el diagrama anterior Conecta la tuber a de salida del ca o de la ba era la tuber a de salida del ca o de la ba era deb...

Page 28: ...D girando la tapa en el sentido de las manecillas del reloj NOTA El limitador de la v lvula puede configurarse para permitir acceso parcial o total al agua caliente al limitar hasta d nde puede girars...

Page 29: ...seada temperatura m xima del agua Para agua m s fr a ajusta el aro de retenci n del l mite rojo 1 hacia la derecha y vuelve a instalarlo 1 en el conjunto del cartucho 2 Para agua m s caliente ajusta e...

Page 30: ...l cuerpo de la v lvula D NOTA Rota el v stago del cartucho 1 hacia la derecha para cortar el suministro de agua antes de instalar la manija 11 C mo instalar la placa protectora y la llave Instala la p...

Page 31: ...ormalmente por el ca o de la ba era J Para activar la ducha abre la v lvula y hala la perilla 1 hacia arriba Sost n la perilla 1 hasta que el agua corra de forma continua desde el brazo de la ducha B...

Page 32: ...traci n del ca o es menor a 0 01 GPM esto ser a normal O considera las siguientes causas La tuber a usada entre la v lvula y el ca o de la ba era no es de 1 2 plg Las tuber a IPS o de COBRE son incorr...

Page 33: ...i n N mero de Pieza 1 RP80657 2 Brazo de la ducha RP38016 3 Cabezal de la ducha RP38411 4 Aro t rico RP60101 5 Cartucho RP20075 6 Aro t rico RP60091 7 Tuerca del bonete RP70437 8 Funda RP80540 9 Inver...

Page 34: ...de regresar a la tienda llama al servicio al cliente de Glacier Bay de lunes a viernes entre 8 a m y 7 p m y los s bados entre 9 a m y 6 p m hora est ndar del Este 1 855 HD GLACIER 1 855 434 5224 HOME...

Reviews: