Verify that the
MG IP
is set
to the Third-party Media Gateway IP address (Ex: (192.xx.xx.221)
➢
Set
MG Port
to
2427
MAPS™ MGCP configured as MG1 (PC #2)
•
Invoke
MAPS™ MGCP
application installed on the PC.
•
The Protocol Selection window is prompted with the following settings:
➢
Protocol Standard as
MGCP
➢
Protocol Version as
IETF
➢
Select Node as
Media Gateway
➢
Click
OK
•
On the Test Bed Default window, load
TestBedDefault
configuration and check for the settings as below:
➢
Set the MG IP to 192.xx.xx.154 (PC IP address where MG is running)
➢
Set MG Port to 2427
➢
Set the MGC IP address where the MGC is running.
➢
Set MGC Port to 2427
➢
Enable RTP Traffic
➢
Set Enable RTP Session as True
➢
Choose RTP Hardware Interface Type as “GL’s High Density Interface Card” (If you have purchased PKS109 -
HD RTP Traffic License)
➢
Set the Media IP address same as MG IP address (192.xx.xx.220)
MAPS™ MGCP configured as MG2 (PC #2)
•
Invoke another instance of
MAPS™ MGCP
application installed on the PC.
•
The Protocol Selection window is prompted with the following settings:
➢
Protocol Standard as
MGCP
➢
Protocol Version as
IETF
➢
Select Node as
Media Gateway
➢
Click
OK
•
On the Test Bed Default window, load
TestBedDefault
configuration and check for the settings as below:
➢
Set the
MG IP
to 192.xx.xx.155 (PC IP address where MG is running)
➢
Set
MG
Port to
2427
➢
Set the
MGC IP
address where the
MGC
is running.
➢
Set
MGC Port
to
2427
➢
Enable RTP Traffic
➢
Set Enable RTP Session as
True
➢
Choose RTP Hardware Interface Type as “GL’s High Density Interface Card” (If you have purchased PKS109 -
HD RTP Traffic License)
➢
Set the Media IP address same as MG IP address (192.xx.xx.221)
•
Select
Editor
→
Profile Editor
and load
MG_Profiles
on both
MG1
and
MG2
. Make sure that options are set as shown
below.
➢
Codec Options
: PCMU
➢
Specify the Packetization Time in Msec
➢
Traffic Type as
Auto Traffic File
➢
Traffic Direction as
Tx
only
➢
Impairment Type
None
•
Click
Start
to start MG and MGC testbed setup on both the PCs. Verify that the SIP and RTP core console window is displayed