GJD RADIUS LUX Quick Start Manual Download Page 2

TO RESET THE UNIT BACK TO FACTORY SETTINGS:

EITHER:

OR:

WHEN INSTALLING THE RADIUS LUX ENSURE THE WIRING
DOES NOT PRESS ON THE TAMPER SWITCH OR PROGRAM BUTTON.

Reset back to factory settings.
RED movement indicator has no pulse count.
Lighting activates with movement 24 hours.
RED indicator illuminates when the light level is too high for

.

the

RADIUS LUX to activate the room lighting.

The number of beams that have to be crossed to trigger the unit.
1 will give a fast response.
2 gives better immunity with good response.
3 gives highest immunity to false activations in poor environments

....

but is less responsive.

Pass through areas when natural lighting is insufficient.
Normal office requirements when increased illumination is required.
Iinspection areas when bright illumination is required.
Will operate the lighting in response to movement 24 hours.

NPC:
24HR:
LUX:

PULSE COUNT:

LUX light level:
(as a guide)

3

Unplug the +/- 12VDC terminal block from the unit whilst
the power is connected.
Press and HOLD the program button whilst the terminal
block is
reconnected to the unit, then release the button.
Select the factory setting from the programming table
ie. 2x GREEN flashes, 1x RED flash

2.

20.

100.

24HR.

.

1x

RANGE metres*

PULSE COUNT**

LED MONITOR

LUX light level*

'S' TIME mins*

8

12

15

2

3

4

5

OFF

ON

NPC

LUX

5

20

50

24HR

100

5

3

2

1

8

12

16

24

32

2x

3x

4x

5x

GREEN SELECTIONS

factory settings are highlighted

2

1

* = approx.

** = alarm output

and LED only

RED OPTIONS

'A' TIME mins*

0

8s

1

2

4

8

16

24

32

6x

1x

2x

3x

4x

5x

6x

7x

8x

9x

All programmed functions are saved if power is removed from the unit.

4

Mount indoors in a dry position on a rigid surface to avoid movement of the
detector. The multi curtain beam pattern allows the unit to be mounted
between 2 and 4 metres high without the need to align the beam pattern. If
the unit is mounted high the blind area below the detector will increase
( see beam pattern ). The ideal position for the unit is one which detects
movement across its field of view ( not towards the unit ) which will give
the best detection response.

As the

detects a heat change in its field of view, AVOID:-

Radiated, convected heat sources, and ventilation ducts.
Direct and reflected sunshine.
Position the unit far enough away from light fittings to prevent excessive
heat or light affecting the normal operation of the unit.

TO SEPARATE THE

:

(1)

Slacken the screw at the base of the unit

DO NOT REMOVE.

(2)

Ease the bottom of the front lens assembly forwards.

(3)

Ease the assembly downwards.

Mount the rear mounting plate in the selected position using the supplied
screws/fixings. Avoid over tightening the screws or the rear mounting plate
will be distorted.

Standard alarm cable is recommended for all connections. Remove the outer
sleeving from the cable inside the case to make the connections more
flexible and easier to connect. The terminal blocks plug onto the circuit
board and can be removed to ease wiring if required.

Reverse the procedure when assembling the unit, taking care
NOT TO OVER TIGHTEN the base screw or trap wires against the tamper
switch or program button.

CEILING MOUNTING

CORNER MOUNTING

WALL MOUNTING

LEAVE 10cm OF CABLE

REMOVE OUTER CABLE

SLEEVING INSIDE THE CASE

TO MAKE THE CONNECTIONS

MORE FLEXIBLE

SLACKEN SCREW ENOUGH TO FREE

FRONT ASSEMBLY

( DO NOT REMOVE )

VIEW OF REAR MOUNTING PLATE

A S

TAMPER

ALARM

12VDC

PROGRAM

BUTTON

REAR VIEW OF CIRCUIT BOARD

T A M P E R S W I T C H

P R O G R A M B U T T O N

U S E D I N

C O N J U N C T I O N W I T H

T H E F R O N T LE D

I N D I C A T O R F O R

P R O G R A M M I N G

Reviews: