RF CONTINUITY TEST

It is advisable to test the RF signal at the
detector location prior to installation.

To enter the RF continuity test mode - press
the program button on the Opal RFX 'eight'
times. On the eighth press - 'hold' the button
down for 5 seconds until the LED goes out
- the LED indicator will then flash and
transmit one signal per second to the receiver.
The corresponding channel indicator on the
receiver will also flash once per second if
there is a strong RF link established.

This test mode will automatically cancel in
five minutes. Alternatively to cancel the ' RF
continuity test - press and hold the program
button until the LED lights then release.

If it is necessary to conduct a site survey
prior to installation of this equipment it is
advisable to power the RFX-3 Receiver
temporarily with a PP3 (9volt) battery.
Register one detector, then conduct an RF
continuity test as detailed above. As the
signals to the receiver are sent once per
second the optimum position  of both the
Opal RFX and the RFX-3 Receiver can be
easily established .

CHANGING THE RANDOM CODE

In the unlikely event of another radio signal
affecting the correct operation of a single
channel. The Opal RFX detector can generate
an alternative random code.
Press the program button on the Opal RFX
nine times.  On the ninth press 'hold'  the
button down for 5 seconds until the LED
goes out, then release the button

Then erase the code from the RFX-3 Receiver
by holding down that 'channel button' until

the beeps stop, then repeat steps '2' to '6' of
the 'Setup' procedure to register the new
code.

OPAL RFX INSTALLATION

:

During installation the electronics must be
protected against water, as trapped moisture
can effect or damage the unit.
1) First remove the front polythene cover by

pulling forwards, then remove the lens
module by pulling it out of the forked
bracket.

2) Drill the wall to accept the fixing screw

supplied with the wall plug.

3)  Fit the housing to a secure surface. When the

surface is uneven use the 4mm spacer
supplied to ensure that the radio signals
transmitted achieve their optimum distance.

4) Always ensure when replacing the module

that it is the correct way up for  the
correct alignment of the beam pattern.
(See page 7 Multibeam lens data)

TESTING THE OUTPUTS

(Alignment of the detection beams)

The range of the detector increases with-
out the front protective cover. Therefore
the front cover must be fitted to establish
the correct beam pattern alignment and
when testing the outputs.

When the 'program' button is pressed
momentarily the red indicator lights and
pulse count '1' is automatically selected. The
unit can then be aligned. The red indicator
will light on the Opal RFX and the respective
Channel indicator will flash every time a
detection takes place.  This test mode will
automatically cancel five minutes after last
detection. Alternatively, to cancel this  'walk
test mode' press the program button twice.

Summary of Contents for OPAL RFX

Page 1: ...ng Heights variable 3 metres high for multi beam coverage 6 metres high for curtain covage and 1 5 metres for pet immunity mask supplied Processing Non volatile memory Intelligentsignalprocessing Digi...

Page 2: ...CTV 1 2 3 N C N O T 20 55C 12V 35mA N C TAMPER CCTV 3 CCTV 2 CCTV 1 LO A1 A2 A3 S RF1 RF2 RF3 12 13 The RFX 3Receiver monitorstheactive stateofuptothreeOpalRFXpassiveinfra reddetectors The RFX 3 Recei...

Page 3: ...the receiver and plug into the aerial transmitter in the back of the detector see fig 5 Detectionsignals willbeimmediately transmittedtothereceiver fig 5 Repeat Steps 2 to 6 for each detector To check...

Page 4: ...before installationoronsite Oncechangeshavebeen madetheyarestoredinanon volatilememory PROGRAMMING Toamendyourexisting Option and Setting 1 Presstheprogrambuttononthedetector onceforthenumberofthereq...

Page 5: ...d the button down for 5 seconds until the LED goes out then release the button ThenerasethecodefromtheRFX 3Receiver byholdingdownthat channelbutton until thebeepsstop thenrepeatsteps 2 to 6 of the Set...

Page 6: ...orCCTV applications When mounting higher than boundaryfencesmaskoffanysidebeamsthat falloutsideoftherequireddetectionarea Also ensuring that no obstacles such as walls or large trees for example obstr...

Page 7: ...LONG RANGE 35 METRE SECTION 6 TO 20 METRES SECTION MULTIBEAM OPTIMUM HEIGHT 3 METRES RANGE MAXIMUM MODULE TILT 0 DEGREE 6 10 20 30 35 9 deg 0 6 TO 20 METRES SECTION TOP MULTIBEAM HEIGHT 6 METRES RANGE...

Page 8: ...8 InstallationNotes GJD Limited Bolton England 010704 GJD reserve the right to alter the specification without prior notice Tel 01204 363998 Fax 01204 363991 Email info gjd co uk...

Reviews: