background image

 

Specifications 

Coverage (max) 

90° at 30m, equivalent to 625m

2

 

Reach 

Adjustable 9m to 30m 

Directional adjustment 

±90° horizontal (180°), ±45° vertical (90°) 

Area adjustment (blanking) 

Supplied with, 1 foil label for near/far beam blanking 
and 4 vertical opaque curtains for zone blanking 

Lens 

2 rows of 10 beams 

Sensor 

White light filter prevents false triggering when sunny 

Output A (Alarm) 

Open-collector transistor switch. 12V, 25mA alarm 
current 

Output S (Sensor, daylight) 

Open-collector transistor switch. 12V, 25mA alarm 
current 

Output T (Tamper) 

Volts-free, normally-open switch output 

Tamper switches 

Case open and removal from wall 

Power 

9 to 15V DC 

Current 

4mA at 12V 

Operating Temperature 

-20°C to +55°C 

Protection 

IP55, high-impact ABS housing. Conformal coated 
electronics (moisture and UV protection lacquer) 

Dimensions 

84 x 106 x 72 mm 

Mounting 

Suggested height 3m 

Cabling 

0 to 200m: standard, 4-core, 7/0.2mm alarm cable 

200 to 500m: 8-core, 16/0.2mm (use double cores) 

 

Approvals 

The manufacturer declares that the product supplied is compliant with the provisions of 
the EMC Directive 89/336/EEC amended 92/31/EEC for Electromagnetic Compatibility, 
and the Restriction of Hazardous Substances Directive (RoHS) 2002/95/EC. A 
Declaration of Conformity in accordance with the above directives is held on file with 
the manufacturer. 

 

Summary of Contents for mini Opal

Page 1: ...5 vertical aim adjustment Conformally coated electronics for enhanced UV and moisture resilience Attractive 21st century styling with a protective cover to disguise sensor direction Field of View The...

Page 2: ...5 Figure 2 Sensor 3m high 0 degree tilt 30m range 6 Metres 6 0 10 20 30 15 Figure 3 Sensor 6m high 9 degree tilt 30m range Pet Immunity lower lenses blanked 1 5 0 10 20 30 5 Figure 4 Sensor 1 5m high...

Page 3: ...definitely Mount 1 Choose a mounting position it should Be 60cm 2ft from lamps If possible allow the wiring to be run through the wall Be smooth enough to hold the tamper plate in position and provide...

Page 4: ...f the power before making connections 1 Connect the A S and wires to the screw terminal block on the back of the sensor PCB A S Figure 6 Rear of PCB with Output Connections 1 Optionally connect the ta...

Page 5: ...relay is connected to the A connection it will trigger for every detection and deactivate immediately By connecting the relay to the S connection the external relay stays active from 60s following the...

Page 6: ...the smooth rear side of the lens 3 Adjust the range between 9 and 30 metres using the PCB mounted pot 9 5 lux 30m 24hr Figure 10 Range and lux potentiometers Dusk Adjustment Adjust the lux level for t...

Page 7: ...switch output Tamper switches Case open and removal from wall Power 9 to 15V DC Current 4mA at 12V Operating Temperature 20 C to 55 C Protection IP55 high impact ABS housing Conformal coated electron...

Page 8: ...ited Sales 44 0 1706 363998 Technical 44 0 1706 363990 Fax 44 0 1706 363991 E Mail info gjd co uk Web http www gjd co uk GJD Reserve the right to amend specifications without notice Copyright 2007 GJD...

Reviews: