A

DJUSTMENT

 

TO

 

FACTORY

 

SETTINGS

:

AUX - A

UXILIARY

 

OUTPUT

  

(50mA maximum)

OFF

Internal sounder and auxiliary output disabled.

STD

Internal sounder and auxiliary output active and will emit a
warning tone on each detection when the tone button is selected.

10-30

The auxiliary output time after last detection.

seconds

The internal sounder is as the STD

L

IGHT

 

ON

 

TIME

 

IN

 

MINUTES

1 to 24

The length of the light on time after last detection during darkness.

minutes

The red detector indicators will stay on for this time after the last

detection day and night.

P

ULSE

 C

OUNT

      Walk test

Select this symbol to assist in location/alignment of the detector

beams during daylight installations.When the detector beams are
activated the external lights will stay on for a period of 6 seconds.

1, 2 or 3

After completing the ‘walk test’ function, set the pulse count to
the required level. The pulse count is the number of detector
beams that have to be crossed to trigger the system.
1

will give a fast response.

2

gives better immunity with good response.

3

gives highest immunity to false activations in poor
environments but is less responsive.

When connecting the unit to the electrical supply or when the supply is interrupted,
the indicators will flash for one minute whilst the system settles. Pressing any
button during this time will start normal operation.

AUX

TIME SECS

LIGHT ON

TIME MINS

PULSE

COUNT

30

STD

OFF

10

20

24

1

3

5

10

3

2

1

Internal adjustments panel
The factory settings are shown.

- 3 -