background image

EXCHANGING EMERALD 3000 WITH AND EMERALD 

MK3

If it becomes necessary to exchange an original 

Emerald 3000 (DX10) lighting controller with an 

Emerald MK3 lighting controller then the following 

connection changes need to be applied. 

230 Volt A.C Connections

Emerald 3000 (DX10)          EMERALD MK3

LIVE 

  LIVE 

LIGHT A    

 

LOAD 1 

LIGHT B   

 

LOAD 2 

NEUTRAL 

 

N

12 Volt D.C Connections

S1 

 

S1 ZONE1

S2 

 

S1 ZONE1 

S3 

 

S1 ZONE1 

S4 

 

S2 ZONE2

S5 

 

S2 ZONE2 

S6 

 

S2 ZONE2

AA  

 

A1,A2, OR A3 ZONE1

AB  

 

A1, A2 OR A3 ZONE2

→ - 

 

AUX

SPECIFICATIONS

SUPPLY

230 Vac 50Hz via ELCB/MCB - 

unit fused at 13A

12VDC@ 100mA

GJD Opal XL (6mA) or Elite 

Detectors (10mA) Optional 

external 12VDC piezo sounder 

up to 50mA

LOAD:

Each expansion unit switches 

two channels each up to 

1500W of resistive load or 

1000  Watts of inductive load. 

The inductive load may require 

a ‘snubber’ (suppressor) to 

manage the lamp discharge 

current.

INDICATION:

Six 24 hour detector indicators 

which pulse during detection 

and are steady after detection 

for the duration of the light on 

timer setting.

AUDIBLE

 Internal warning tone which 

sounds on detection day and 

night, and is button selectable. 

It has a steady tone for zone 

one and pulsed tone for zone 

two.

CONTROL

Controls up to 12 x GJD 

detectors. Switches two 

independent areas of lighting 

with manual override when 

required.

OPTIONS

Ability to link both lighting 

areas together.

Ability to have a time auxiliary 

output.

Ability to active lighting when 

linked to an intruder alarm 

panel.

DIMENSIONS

146(W) x 86(H) x 56(D) mm    

MOUNTING

Indoor use only. Mount in a 

clean dry location on a secure 

flat surface.

TEMPERATURE

-10 to +55 Centigrade

CERTIFICATIONS

Self contained  - Class 2 independently mounted control