Giussani Techniques E-PRL User Manual Download Page 9

 

                                                                                                                                                                          

               

 

 

 

The programming procedure is complete and all the USER keys (black)  stored in the lock can now open the lock and all the 
DOWNLOAD keys (blue) stored in the lock can now download the data from the lock while the keys deleted from the memory 
of the lock can no longer perform any operation (lock opening or downloading of the data). 

 

 

The pairing of new keys or the deletion of keys previously paired are independent procedures and may be done in a different 
order than indicated above. The pairing of new keys or the deletion of keys previously matched are independent procedures 
and may be made in a different order than indicated above. For example, you can also choose to only add or only delete. 

 

RESET LOCK WITH MASTER KEY 

Caution: The reset procedure will inhibit the operation of all USER keys (black) and possibly DOWNLOAD key (blue) previously 
paired with the lock by restoring the factory configuration. Therefore, at the end of the operation, the lock will be in the  "Initial 
Programming" waiting state and it can accept any MASTER key (red) for programming.  

 

 

In order to reset the lock, it is necessary to insert and extract the paired MASTER key (red) (used for the initial programming) 
in succession for 5 times  
 

 

Insert and remove the MASTER key (red) 5 (five) times in succession. Verify that the alerts are as follows: 

 

1° insert (1 fast green LED blinks) 
2° insert (1 long green LED blinks) 
3° insert (2 fast green LED blinks) 
4° insert (3 long green LED blinks) 
5° insert (1 long green LED blink and 1 long red LED blink) 
 

The 5

th

 signal on the key (                      ) shows the effective lock reset, it has therefore reverted to the factory settings "Before 

Programming" 
 

 

If the RESET procedure has been started by mistake it will be possible to interrupt it, after the 2nd insertion, at any time before 
the RESET (5th insertion); in order to interrupt the reset procedure, just insert any USER key (black) previously memorized on 
the lock. 
 
 

 

Attention: if the USER key (black) is inserted after the first insertion, the USER key would, as previously indicated, be eliminated 
from the lock: a single long green LED blinks will be emitted and then the red LED (                      ) to indicate the cancellation 
of the key from the lock. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for E-PRL

Page 1: ...E PRL REPROGRAMMABLE ELECTRONIC LOCK MULTI CODE version User manual...

Page 2: ...ck memory p 7 Programmed lock already setup open lock with any USER key p 7 o Pair key to lock memory p 7 o Eliminate key from lock memory p 7 Reset lock with MASTER key p 8 Switching to ACCESS CONTRO...

Page 3: ...lectric shock resistant Self powered system that does not require an electrical system Encrypted and inviolable communication system Over 10 billion combinations Access control via the dedicated GSN K...

Page 4: ...is supplied by the keys OPERATING MODE In the Multi Code version the MASTER key red allows the use of each lock with up to 300 USER keys black and or DOWNLOAD blue Each programmed lock will work only...

Page 5: ...correct position for programming We recommended you perform the mechanical lock installation before programming For assemblies that require programming prior to mechanical installation contact Technic...

Page 6: ...the USER keys black stored in the lock can now open the lock Caution From now on no MASTER key red other than the one used for the initial programming will be able to perform any operation on the lock...

Page 7: ...e repeating the operation Attention in order to avoid an excessive consumption of the batteries contained inside each single key it is advisable once the key has been opened not to leave it in the loc...

Page 8: ...MASTER key red into the lock the key used for initial lock programming 2 2 A single fast blink of the green LED on the MASTER key red indicates the start of the key pairing and cancellation process R...

Page 9: ...ogramming waiting state and it can accept any MASTER key red for programming In order to reset the lock it is necessary to insert and extract the paired MASTER key red used for the initial programming...

Page 10: ...ntrol System User Manual in the Key Recording section DOWNLOAD KEY WITH GSN KEY ACCESS CONTROL SOFTWARE The DOWNLOAD key is the key you need to download and history access log from the locks and to vi...

Page 11: ...d bearing the CMC The MASTER COPY key red will emit a single fast blink of the green LED to indicate the start of the pairing procedure Remove the key from the lock after the above signal has occurred...

Page 12: ...he time of purchase 1 1 Insert the MASTER key red into the lock the key used for initial lock programming 1 2 A single fast blink of the green LED on the MASTER key red indicates the start of the key...

Page 13: ...requirements applicable to the type of product and required by telecommunications regulations in accordance with Directive 2014 30UE and 2011 65 EC using the rules published in the Official Journal of...

Reviews: