Practical assembly

Caution! Installation and assembly of electrical devices may

only be carried out by an electrician.

Switch the supply voltage off! Necessary screws,

pins, and drilling template are included.

1. Drill according to the drilling template (Ø 6 mm).

2. Punch out cable entry (do not use a knife!).

3. Insert cable and screw on socket.

TOP / OBEN must be on top with ceiling mounting

in the direction of the area to be detected.

4. Electrical connection according to the diagram

(see page 12/13). Do not place lines across terminals!

Otherwise, the upper part can not engage.

5. With AP cable entry: Remove appropriate covers for

the cable entry.

6. Put on upper part and engage audibly (guides!).

7. Turn the dome to the left and remove (bayonet).

8. Adjust lens, with ceiling mounting, pivot 90°.

7

Summary of Contents for Tectiv 220

Page 1: ...GB Tectiv 220 Instructions for use With teach in accepts the current brightness as an operating point with the press of a button...

Page 2: ...1...

Page 3: ...e operating time can be adjusted from 1 second to 30 minutes And if you want the Gira Tectiv 220 not to react for 2 hours it can be set to be constantly on or constantly off Even the operating point c...

Page 4: ...ome to the left and remove it 2 Press the red Teach button for at least 3 s do not touch lens The LED will begin to blink 3 Replace the dome and turn to the right After 1 minute the value is saved the...

Page 5: ...continuous hours on the veranda Then the normal monitoring function is active again Buttons Press 1x Light ON for set operating time Press 2x continuous ON for 2 hours Press 3x continuous OFF for 2 ho...

Page 6: ...m sources of disturbance blank out bushes moved by the wind streets that are heavily traveled paths of pets Assembly Cable entry AP Cable entry UP Design Ring can be shifted 3 times depending upon cab...

Page 7: ...se a knife 3 Insert cable and screw on socket TOP OBEN must be on top with ceiling mounting in the direction of the area to be detected 4 Electrical connection according to the diagram see page 12 13...

Page 8: ...essary correct the alignment of the lens 2 blank out sources of disturbance To do this mask off the appropriate segments on the lens with the matching segments of the included screen If this is not en...

Page 9: ...ation height of 2 4 m Near Medium Far Background monitoring Near Medium Far Background monitoring Classification of the segments Near approx 0 to 3 m Middle approx 3 to 9 Far approx 9 to 16 m Backgrou...

Page 10: ...briefly switched on for 1 second and then switched off again e g for a gong After that movement is not registered for 9 seconds Switching the LED off and on The movement detection is signaled by the...

Page 11: ...ip width 4 mm 1 Push design ring forward until it stops 2 place the screwdriver in both holes one after the other and pry on the guides slightly in the direction of the design ring 3 Pull off Tectiv 2...

Page 12: ...3x continuous OFF for 2 hours continuous ON continuous OFF returns to normal moni toring function after 2 hours T Button opener Reversing switches Replace existing reversing switches with buttons Func...

Page 13: ...light is deactivated During activation the S1 is used for switching not the S2 S switch Parallel switching Parallel switching of several Gira Tectiv 220 With the parallel switching the switching capa...

Page 14: ...rescent lamps 1200 W Power input approx 1 W deactivated condition Power input approx 5 W activated condition Surrounding temperature 25 C to 55 C Make time approx 1 second up to 30 minutes Brightness...

Page 15: ...eral terms of sales Compliance with the claim deadline is to be demonstrated by voucher of the purchase date by means of an included invoice delivery note or similar documents 3 The purchaser is defin...

Page 16: ...Gira Giersiepen GmbH Co KG Postfach 12 20 42461 Radevormwald Germany Telefon 00 49 2195 602 0 Telefax 00 49 2195 602 339 Internet www gira de E Mail info gira de 4817 11 10 08 00...

Reviews: