Wireless dimming actuator, 4-gang
For ohmic-inductive mixed load, maximum 50% proportion of ohmic load. Otherwise in-
correct calibration of the dimmer may result.
Only subject load outputs switched in parallel to up to 95%.
The minimum load of parallel switching of load outputs is 250 VA.
Figure 6: Connected load
If the operating mode is set to HV
{
LED trailing edge phase control, the maximum
connected load for LED lamps increases to typ. 200 W.
Mixed load
ohmic-inductive
20 ... 250 VA
ohmic-capacitive
20 ... 250 VA
capacitive-inductive
not permitted
Ohmic and HV LED
typ. 3 ... 50 W
Ohmic and compact fl lamp.
typ. 3 ... 50 W
Power boosters
See power booster instructions
Total length power cable per channel
100 m
Fitting width
144 mm / 8 module
Bus connection
Rated voltage
DC 12 V SELV
Current consumption
10 mA
Connection, Bus
device connection terminal
Cable length
max. 3 m
6
Parameter list
The device parameters can be changed with the eNet server:
Device and channels
Parameters
Setting options, Basic setting
Explanations
Function
Light, unused
Basic setting: Light
Light
The channel is integrated for
the "Lighting" central function
in the eNet SMART HOME
app.
Unused
The channel is not displayed
in the eNet SMART HOME
app and is disabled for use in
the commissioning interface.
9 / 19
32578622
10867484
01.10.2019