Pushbutton sensor 4 Standard / Komfort System 55

9

Accessories

Individually labelled rocker sets are available from the Gira inscription service www.bes-
chriftung.gira.de.

Rocker set, 1-gang for pushbutton sensor 4

Order no. 5751 ..

Rocker set, 1-gang, inscribable, for pushbutton sensor 4

Order no. 5761 ..

Rocker set, 1-gang, inscribable, for pushbutton sensor 4

Order no. 5771 ..

Rocker set, 2-gang for pushbutton sensor 4

Order no. 5752 ..

Rocker set, 2-gang, inscribable, for pushbutton sensor 4

Order no. 5762 ..

Rocker set, 2-gang, inscribable, for pushbutton sensor 4

Order no. 5772 ..

Rocker set, 4-gang for pushbutton sensor 4

Order no. 5753 ..

Rocker set, 4-gang, inscribable, for pushbutton sensor 4

Order no. 5763 ..

Rocker set, 4-gang, inscribable, for pushbutton sensor 4

Order no. 5773 ..

Remote sensor

Order no. 1493 00

10 Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your re-
sponsible salesperson (specialist trade/installation company/electrical specialist trade). They will
forward the devices to the Gira Service Center.

Gira
Giersiepen GmbH & Co. KG
Elektro-Installations-
Systeme

Industriegebiet Mermbach
Dahlienstraße
42477 Radevormwald

Postfach 12 20
42461 Radevormwald

Deutschland

Tel +49(0)21 95 - 602-0
Fax +49(0)21 95 - 602-191

www.gira.de
[email protected]

16 / 16

32406202

10868646

29.06.2022

Summary of Contents for 5011 00

Page 1: ...er no 5042 00 Pushbutton sensor 4 Komfort 3 gang System 55 Order no 5043 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled pe...

Page 2: ...1 Device components 3 gang standard installation location horizontal rockers Figure 2 Device components 3 gang installation location turned by 90 vertical rockers a Operating rockers accessory b Stat...

Page 3: ...ure 3 Device components rear side c Device connection terminal for remote sensor only for comfort device variant d Device connection terminal KNX e Retaining clips for device fixation at the supportin...

Page 4: ...com missioning During mounting the device certificate must be removed from the device and stored securely Planning installation and commissioning of the device are carried out with the aid of the ETS...

Page 5: ...tton LED functions orientation lighting and night reduction can be set separately LED functions orientation lighting alarm signalling and night reduction can be set separately Brightness of LED adjust...

Page 6: ...tch Short press on button Dim Long press on the button The dimming process ends when the button is released Move Venetian blind Long press on button Stop or adjust Venetian blind Short press on button...

Page 7: ...d installation location or vertically turned by 90 installation location For horizontal installation standard installation location the top of the push button sensor is labelled with TOP For vertical...

Page 8: ...rting frame in the right orientation standard installation location or turned by 90 on an appliance box Note the TOP marking Use the supplied box screws Pull off start up rockers from push button sens...

Page 9: ...ndard Komfort System 55 The physical address is programmed see chapter Commissioning Page 10 in the next work step The rockers can then be mounted see chapter Mounting the rock ers Page 12 9 16 324062...

Page 10: ...am The device is for use All status LEDs are switched off while the application program is programmed As soon as the programming is successfully completed the status LEDs carry out their parameterised...

Page 11: ...address 15 15 255 firmware re mains in place The device must then be recommissioned with the ETS In secure operation A master reset deactivates device security The device can then be recommissioned wi...

Page 12: ...the rocker into place Press in the middle of the rocker Figure 7 Figure 7 Press lightly in the middle of the rocker The rocker snaps into place Device is ready for operation In order to optimise the g...

Page 13: ...55 7 4 Dismantling Carefully pull the push button sensor forward together with the cover frame Pull the rockers on one side to loosen them from the push button sensor Figure 8 Dismantle the push butto...

Page 14: ...e side at the notch in the cover of the labelling field to separate from the rocker Figure 10 The labelling field is uncovered Figure 9 Feel for a notch in the labelling field cover Figure 10 Remove t...

Page 15: ...t Y 2x2x0 8 Protection class III Installation dimensions Figure 11 Construction height A 11 9 mm A 12 5 mm stainless steel rocker set Installation depth B 13 8 mm Connection cable remote sensor see ac...

Page 16: ...4 Order no 5753 Rocker set 4 gang inscribable for pushbutton sensor 4 Order no 5763 Rocker set 4 gang inscribable for pushbutton sensor 4 Order no 5773 Remote sensor Order no 1493 00 10 Warranty The w...