Gira 1288 Series Operating Instructions Download Page 2

Start-up

Door station – home station assignment 

Door opener – door station assignment:

Operation

“System progr.” button

If the “System progr.” button is pressed for 
3 s, the door communication system is 
switched to programming mode. The yellow 
LED next to the programming button 
flashes to indicate that programming mode 
is active. 

“Door-opener progr.” button

The “Door-opener progr.” button has two 
functions:

1. Switch on door opener programming 

mode:
If the “Door-opener progr.” button is 
pressed for 3 s while the system is in pro

-

gramming mode, the door opener pro

-

gramming mode is activated. 
The yellow LED next to the “Door-opener 
progr.” button flashes to indicate that door 
opener programming mode is active.

2. Operation of the connected door opener.

Briefly pressing the “Door-opener progr.” 
button activates the door opener for the 
set door opener time.
The yellow LED next to the “Door-opener 
progr.” button lights up during the switch

-

ing time.

“Door-opener time” setting controller

The activation time of the door opener can 
be continuously adjusted using the “Door-
opener time” setting controller. The adjust

-

ment time ranges from 1 s to 10 s. The 
potentiometer can be adjusted using a 
screwdriver with a 3 mm blade.

Indicators 

“Operation” indicator

During fault-free normal operation, only the 
green “Operation” LED lights up. It signals 
that the device is being supplied with mains 
voltage.

“Overload” indicator

The video control device has electronic 
overload protection that protects the elec

-

tronics of the control device against short 
circuits and overload on the bus line.The 
overload protection is activated if the bus 
line is short-circuited due to an installation 
error, for example, or if too many bus 
devices/bus loads have been connected.
The red “Overload” LED signals both a short 
circuit and an overload. The length of time 
the LED flashes corresponds to the time 
that the bus voltage is switched off in the 
event of an error. After the error has been 
corrected, the LED continues to flash for up 
to 5 s.
In case of a permanent overload (or short 
circuit), the bus voltage is switched off for 
approx. 180 s after the third overload is 
detected. During this switch-off phase, the 
“System progr.”, “Door-opener progr.” and 
“Overload” LEDs flash.
After the error has been corrected, the LEDs 
continue to flash for up to 180 s.

Technical data

Primary rated 
voltage:

AC 230 V, 50 Hz

Secondary rated 
voltage:

SELV 26 V DC ± 2 V

Secondary rated 
current:

700 mA 

Continuous load

Overload cut-off
from approx. 900 mA
1.15 A peak load

(max. 5 s)

Protection type:

IP 20

Screw terminals:

0.6 mm  
to 2.5 mm

2

Door opener output: 12 V AC, 1.1 A

(switched for the set 
door opener time)

Door opener time:

Can be set 

continuously

1 s to 10 s

Power-on time
Door opener: 

25% (max. 10 s ON,
 then 30 s OFF)

Operating 
temperature:

- 5 °C to + 45 °C

Dimensions: 

8 MW DRA housing 

Warranty

The warranty is provided by the retailer in 
accordance with the statutory require

-

ments.
Please hand over or send faulty devices, 
postage exempt, and with a description of 
the problem to your supplier (retailer/instal

-

lation company/electronics retailer). 
They will forward the devices to the Gira 
Service Centre.

Further information

Further information on application scenar

-

ios, system limits, topologies, installation 
and start-up can be found in the “System 
basics for door communication”
in the Gira download area:

Control device

Press “System progr.” button (3 s),

 “System progr.” LED flashes.

Door station

Press call buttons in teach-in sequence 

(WS1, WS2, WS3) (3 s),

 until short tone = release button,

then long tone.

Home station 3

Press “Light” button (3 s),

until short tone = release button,

then long tone = assignment OK.

Control device

Press “System progr.” button briefly,

 “System progr.” LED off.

Home station 2

Press “Light” button (3 s),

until short tone = release button, 

then long tone = assignment OK.

Home station 1

Press “Light” button (3 s),

until short tone = release button, 

then long tone = assignment OK.

Door station

Press call buttons in teach-in sequence 

(WS1, WS2, WS3) (3 s),

 until short tone = release button,

then long tone.

Control device

Press “System progr.” button (3 s),

 “System progr.” LED flashes.

Press “Door-opener progr.” button (3 s),

 “Door-opener progr.” LED flashes.

Door station

Press any call button (3 s),

until short tone = release button, 

then long tone = assignment OK.

 

 Door opener is activated.

Control device

Press “Door-opener progr.” button briefly.

 “Door-opener progr.” LED off.

Press “System progr.” button briefly,

 “System progr.” LED off.

Systemprogr.