Safety information

Serious injury, fire or damage to property 
possible. Read and observe these instruc

-

tions completely.
These instructions are an integral compo

-

nent of the product and must remain with 
the end customer.

Intended use

- Provision of bus voltage (26 V DC ± 2 V) 

for the door communication system

- Control of up to 15 colour cameras (5 vid

-

eo door stations and 10 DCS camera 
gateways),

- Power supply of 

- up to 31 video devices (e.g. 28 home 

stations, 2 door stations with colour 
camera, 1 DCS switching actuator)

- up to 70 audio devices
- up to 2 colour cameras (more with ad

-

ditional power supply)

- Call-button illumination (max. 15, the 

number of call-button illuminations that 
can be supplied with power depends on 
the system size and the number of 
home stations operated in parallel)

- Provision of the door opener control incl. 

power supply (12 V AC, 1,1 A) for the door 
opener.

- Activation of the entire door communica

-

tion bus system’s programming mode.

- Electronic overload, short-circuit and 

overtemperature protection.

- “Operation” LED indicator (mains volt

-

age), overload/short circuit, 

- Adjustable door opener activation time.

Assembly

For drip and splash-proof installation, 
mount the control device on a top-hat rail in 
the distributor.
The mains and bus connection is made 
using screw terminals.
The mains connection must be made using 
an all-pole mains switch with a contact 
opening of at least 3 mm.
The functional earth must be connected 
using a distributor block.
The control device’s ventilation slits must 
not be obstructed.

Electrical connections (Fig. 1)

L, N

Mains connection terminals L and N (AC 
230 V, 50 Hz).

 (Functional earth)

A functional earth is connected to this ter

-

minal for functional reasons.
Connect the earth potential to the earth ter

-

minal with a suitable line (not a green/yel

-

low line).

Bus

Power supply output of the Gira door com

-

munication bus with a regulated DC voltage 
(26 V DC ± 2 V, 700 mA).

(Door opener output 230 V~/max. 2 A)

A door opener that 

cannot

 be connected to 

the “12 V~” terminals due to its electrical 
values (e.g. very low-ohm or 24 V) can be 
connected to the equipotential-bonding 
relay contact with an external power supply 
(230 V~, max. 2 A).

12 V~ (door opener output 12 V~)

The 12 V~ output is used to supply power to 
and control the door opener (8–12 V, max. 
1.1 A).

Electrical devices may only be 
installed and connected by a qua

-

lified electrician.

EN

Remove blank plug

Before connection, remove the blank plug 
from the terminal 

.

No permanent 12 V output

Power is not continuously supplied at the 
door opener output. The 12 V supply at the 
door opener output is only active for the 
door opener time specified on the setting 
controller.