background image

Blind controller insert DC 24 V 

Order-No. : 0388 00 

Operating instructions 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

To supply the insert and to control the extension inputs it is necessary to use a power 
supply unit that provides DC 24 V SELV. This ensures reliable isolation between the 
primary and secondary sides. 

Risk of injury. Use the device only for controlling Venetian blind and roller shutter 
motors or awnings. Do not use it to switch other loads. 

Use only Venetian blind drives with mechanical or electronic limit switches. Check the 
limit switches for correct adjustment. Observe the specifications of the motor 
manufacturers. Device can be damaged. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Figure 1 

(1)  24 V insert 
(2)  Frame 
(3)  Shutter cover 
(4)  Terminals 
(5)  Space for sensor terminal block 

3 Function 

Intended use 

Control of electrically-driven Venetian blinds, shutters and awnings that are operated with 
DC 24 V SELV 

Operation with suitable shutter cover 

Installation in appliance box to DIN 49073 

1/8 

32545312 

17.05.2011 

Blind controller insert DC 24 V 

10499098  I00 

Blind control system 

Summary of Contents for 0388 00

Page 1: ...tter motors or awnings Do not use it to switch other loads Use only Venetian blind drives with mechanical or electronic limit switches Check the limit switches for correct adjustment Observe the speci...

Page 2: ...tom of cover for longer than one second The Venetian blind moves in the desired direction to the end position or stops when the button is pressed again Adjusting the slats o Press top or bottom of cov...

Page 3: ...n appliance box terminals must be at the bottom o Attach the frame and the cover o Check function If the blind shutter moves in the wrong direction exchange the connections Connecting an extension DAN...

Page 4: ...or is determined by the polarity of the two extension inputs Connection illustration Figure 4 shows the direction of motion of the blind shutter for the depicted connection assignments Figure 5 Insert...

Page 5: ...h extension inputs Figure 7 Connection diagram for two inserts supplied via two power supply units o Connect extension according to connection diagram Figure 5 Figure 6 or Figure 7 Installing the sens...

Page 6: ...the sensor cable use only shielded cables Recommendation J Y ST Y 2x2x0 6 mm o Insert the cable through the hole 11 in the insert and route it through the cable duct 12 to the terminal block 13 Figur...

Page 7: ...e earth is identified For the adapter and the extension cable the sun is identified The earth is the middle cable i Interchanging the connections will result in malfunctions i If the sun and glass bre...

Page 8: ...mm 6 2 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to you...

Reviews: