6. Operation
.19.
6.4 Advanced Info - Technicians Only
After enter the correct password the Main Menu will display a screen and be able to access
to the following information.
1. Alarm Message
2. Temperature
3. Standard No.
4. Version
5. Communication Data
The screen can be scrolled manually by pressing the UP/DOWN keys. Pressing the ENTER
key gives access to a submenu. Press the ESC key to return to the Main Menu.
6.4.1 Alarm Message
The display shows the 10 latest alarm messages (see Figure 6.6). Screens can be scrolled
manually by pressing the UP/ DOWN keys. Press the ESC key to return to the previous
menu.
Alarm0: OV-G-V
Time: 27-11 Data: 7171
Figure 6.6 Alarm Message
NOTE:
To access to this area is for fully qualified and accredited technicians only.
Please enter the password to
“Advanced Info.” and “Advanced setting”
YES=<ENT> NO=<ESC>
Password:0000
Figure 6.5 Enter password
Select “Advanced Info.” from the Main Menu. The screen will require the password as below
The default password is “0010". Please press “down” to move the cursor, press “up” to
select the number.
.18.
6.3 Settings
The following submenus are displayed when the Settings menu is selected:
1. Set Time
2. Set Address
6.3.1 Set Time
This function allows time and date setting. When this function is selected, the LCD will
display a screen as shown in Figure 6.3.
NEXT=<ENT> OK=<ESC>
01-01-2010 16:37
Figure 6.3 Set Time
Press the UP/DOWN keys to set time and data. Press the ENTER key to move from one
digit to the next (from left to right). Press the ESC key to save the settings and return to
the previous menu.
6.3.2 Set Address
YES=<ENT> NO=<ESC>
Set Address: 02
Figure 6.4 Set Address
Press the UP/DOWN keys to set the address. Press the ENTER key to save the settings.
Press the ESC key to cancel the change and return to the previous menu.
6. Operation
This function is used to set the address when the inverter is connected to the PC. The
address number can be assigned from “01”to “99”(see Figure 6.4). The default address
number of Solis Single Phase Inverter is “01”.