Gingerway GW-4361 Instruction Manual Download Page 2

Power Supply

100 

~ 

240VAC  50/60HZ

Standby consumption: <0.5W

Maximum consumption: <2W

Outputs

Up to 5 relays 

Load current: rated current 1A, surge current 3A

User Interface

5 backlit capacitive touch keys

Backlit 128*64 B/W graphic LCD 

RF

Frequency:  433MHz(315M, 868M, 915M are customizable)

Transmit power: 10dbm

Receiving sensitivity ≤-105dbm 

Temperature

Setting temperature: 5-35

Environmental temperature: 0-50

Precision: ±1

 

Probe: NTC

Installation

CCC(86mm*86mm) 

CE(86mm*86mm) 

Wiring

2 power-supply wirings

5 ways output wirings

Cross-sectional area of conductor: 

1 * 1.0 mm² ~ 1 * 2.5 m²

Timer

Minimum programming interval: 1 hour

Maximum programming interval: 12 hours

Operating Environment

Environmental temperature:  0

  to 50 

Relative humidity: 10% to 90% 

Certification

CE Mark Low Voltage

CE Mark EMC  

CE RADIO

Shell

94-V0 PC

Dimensions & Weight

W 86mm x L 86mm x H 14.7mm (Front Panel)

W 86mm x L 86mm x H 36.7mm (Total)

Weight: 155g 

 

Technical parameters

Restore factory settings

1.Turn off the power of smart thermostat.

2.As soon as the power, long press the leftmost and righmost 

keys(ON-OFF key and Down key) at the same time for 10 

seconds.

3.The smart thermostat will be restored to factory settings.

Binding

Long press the ON-OFF key for 12 seconds, start to bind with 

main controllers, such as gateway, remote controller, etc.

Timer setting

Long press the "M/Timer" key for 5 seconds, the timer will be 

displayed. Then long press the "M/Timer" key again, the timer  

will be cancelled. Press the "Up" and "Down" keys can adjust 

the timing.

In off-state, you can set a timming to start up the thermostat; 

In on-state, you can set a timing to shut down the thermostat.

Low temperature protection

In off-state, long press the "fan" key for 5 seconds can set the 

thermostat to low temperature protection mode, long press 

the "fan" key once again can cancel it.

Low temperature protection

When the room temperature 

is below 5

, the thermostat will automatically start heating; 

When the room temperature rises to 7

, the thermostat will 

automatically stop heating.

Sleep mode setting

In on-state, long press the "fan" key for 5 seconds can set  the 

thermostat to sleep mode, long press the "fan" key once again 

can canel the sleep mode.

Sleep mode: 

Under cooling or heating mode, the thermostat 

reverse heating or cooling 1

 in the 1st hour, and then 

reverse heating or cooling 1

 in the 2nd hour. Then keep it to 

the end of sleep, give you a comfortable sleep environment. 

Usage

FAN

L

N

L

M
H

ON

VALVE

3-SPEED FAN

100 

 240VAC 50/60H

Z

2 (V2F3C)
3 (V2F3S)

FAN

L

N

L

M
H

ON

OFF

HOT 

VALVE

3-SPEED FAN

100 

 240VAC 50/60H

Z

COOL 

VALVE

5 (V4F3C)
6 (V4F3H)

Warranty Terms

Gingerway products are guaranteed for 2 years since the date of purchase. 

During the warranty period, if Gingerway products malfunction(not contain artificial 

damages) under normal circumstances, they can be free repaired or exchanged 

at local dealer with the purchase invoice.

1. If due to quality failure during the warranty period, the maintenance is free in 

first year, only the component cost will be charged in the second year.

2. Disassembling Gingerway product components without the permission of 

our company or the local client center, our company will no longer bear the free 

warranty responsibility .

Note: Shenzhen Gingerway Technologies Co., Ltd reserves the right of final 

explanation for above terms.

0678

Shenzhen Gingerway Technologies Co., Ltd. 

Address: 3-Floor, Building A6, Xingye Industrial Park, Zhongshanyuan No.2 Road, 

Nanshan District. Shenzhen, Guangdong, China.

Tel :0755 -28779595  Fax :0755 -28779405

Website: www.gingerway.com

1. Please hire professional electrician to install or disassemble this product. The 

power must be cut off before installing or disassembling.

2. This product is forbidden to be installed in outdoors, bathroom and other humid 

environments.

3. The wiring must be in accordance with instruction manual, otherwise the 

products may be damaged.

Notice

(7)

ON

1         2         3

7(HEATER)

L

N

ON

OFF

VALVE

100 

 240VAC 50/60H

Z

Reviews: