Power Supply
100
~
240VAC 50/60HZ
Standby consumption: <0.5W
Maximum consumption: <2W
Outputs
Up to 5 relays
Load current: rated current 1A, surge current 3A
User Interface
5 backlit capacitive touch keys
Backlit 128*64 B/W graphic LCD
RF
Frequency: 433MHz(315M, 868M, 915M are customizable)
Transmit power: 10dbm
Receiving sensitivity ≤-105dbm
Temperature
Setting temperature: 5-35
℃
Environmental temperature: 0-50
℃
Precision: ±1
℃
Probe: NTC
Installation
CCC(86mm*86mm)
CE(86mm*86mm)
Wiring
2 power-supply wirings
5 ways output wirings
Cross-sectional area of conductor:
1 * 1.0 mm² ~ 1 * 2.5 m²
Timer
Minimum programming interval: 1 hour
Maximum programming interval: 12 hours
Operating Environment
Environmental temperature: 0
℃
to 50
℃
Relative humidity: 10% to 90%
Certification
CE Mark Low Voltage
CE Mark EMC
CE RADIO
Shell
94-V0 PC
Dimensions & Weight
W 86mm x L 86mm x H 14.7mm (Front Panel)
W 86mm x L 86mm x H 36.7mm (Total)
Weight: 155g
Technical parameters
Restore factory settings
1.Turn off the power of smart thermostat.
2.As soon as the power, long press the leftmost and righmost
keys(ON-OFF key and Down key) at the same time for 10
seconds.
3.The smart thermostat will be restored to factory settings.
Binding
Long press the ON-OFF key for 12 seconds, start to bind with
main controllers, such as gateway, remote controller, etc.
Timer setting
Long press the "M/Timer" key for 5 seconds, the timer will be
displayed. Then long press the "M/Timer" key again, the timer
will be cancelled. Press the "Up" and "Down" keys can adjust
the timing.
In off-state, you can set a timming to start up the thermostat;
In on-state, you can set a timing to shut down the thermostat.
Low temperature protection
In off-state, long press the "fan" key for 5 seconds can set the
thermostat to low temperature protection mode, long press
the "fan" key once again can cancel it.
Low temperature protection
:
When the room temperature
is below 5
℃
, the thermostat will automatically start heating;
When the room temperature rises to 7
℃
, the thermostat will
automatically stop heating.
Sleep mode setting
In on-state, long press the "fan" key for 5 seconds can set the
thermostat to sleep mode, long press the "fan" key once again
can canel the sleep mode.
Sleep mode:
Under cooling or heating mode, the thermostat
reverse heating or cooling 1
℃
in the 1st hour, and then
reverse heating or cooling 1
℃
in the 2nd hour. Then keep it to
the end of sleep, give you a comfortable sleep environment.
Usage
FAN
L
N
L
M
H
ON
VALVE
3-SPEED FAN
100
~
240VAC 50/60H
Z
2 (V2F3C)
3 (V2F3S)
FAN
L
N
L
M
H
ON
OFF
HOT
VALVE
3-SPEED FAN
100
~
240VAC 50/60H
Z
COOL
VALVE
5 (V4F3C)
6 (V4F3H)
Warranty Terms
Gingerway products are guaranteed for 2 years since the date of purchase.
During the warranty period, if Gingerway products malfunction(not contain artificial
damages) under normal circumstances, they can be free repaired or exchanged
at local dealer with the purchase invoice.
1. If due to quality failure during the warranty period, the maintenance is free in
first year, only the component cost will be charged in the second year.
2. Disassembling Gingerway product components without the permission of
our company or the local client center, our company will no longer bear the free
warranty responsibility .
Note: Shenzhen Gingerway Technologies Co., Ltd reserves the right of final
explanation for above terms.
0678
Shenzhen Gingerway Technologies Co., Ltd.
Address: 3-Floor, Building A6, Xingye Industrial Park, Zhongshanyuan No.2 Road,
Nanshan District. Shenzhen, Guangdong, China.
Tel :0755 -28779595 Fax :0755 -28779405
Website: www.gingerway.com
1. Please hire professional electrician to install or disassemble this product. The
power must be cut off before installing or disassembling.
2. This product is forbidden to be installed in outdoors, bathroom and other humid
environments.
3. The wiring must be in accordance with instruction manual, otherwise the
products may be damaged.
Notice
(7)
ON
1 2 3
7(HEATER)
L
N
ON
OFF
VALVE
100
~
240VAC 50/60H
Z