Important Notes 

1.1  Safety and Hazard Advice 

In order to avoid personal injuries and damage to property, you must read and understand the following 

safety instructions and hazard warnings prior to installation and use of this device. Keep this documentation 

(and manual) always near the device. 

1.1.1  Proper Use and Intended Purpose 

The GLA618 is an extension device for the G.i.N. data logger, which is mainly used in the automotive and 

commercial vehicles industries. The device is an AUX

+

 splitter designed for industrial needs that can connect 

multiple additional devices to a data logger via the AUX

interface. 

The device may only be operated in a closed state. In particular, PCBs must not be visible. The device may 

only be operated according to the instructions and descriptions of this manual. Only suitable electric power 

supply designed for the device and accessories manufactured or approved by G.i.N. GmbH may be used. 
The device is exclusively designed for use by skilled personnel as its operation may result in serious 

personal injuries and damage to property. Therefore, only those persons may operate the device who have 

understood the possible effects of the actions which may be caused by the device; are specifically trained in 

handling the device, bus systems and the system intended to be influenced; and have sufficient experience 

in using the device safely. 
To ensure the operation of the GLA618, connected cables should not exceed a length of 30 m. 

1.1.2  Hazards 

The device may control and/or otherwise influence the behaviour of electronic control units. Serious hazards 

for life, body and property may arise, in particular, without limitation, by interventions in safety  relevant 

systems (e.g. by deactivating or otherwise manipulating the engine management, steering, airbag and/or 

braking system) and/or if the device is operated in public areas (e.g. public traffic, airspace). Therefore, you 

must always ensure that the device is used in a safe manner. This includes, inter alia, the ability to put the 

system in which the device is used into a safe state at any time (e.g. by „emergency shutdown“), in 

particular, without limitation, in the event of errors or hazards.  
Comply with all safety standards and public regulations which are relevant for the operation of the system. 

Before you operate the system in public areas, it should be tested on a site which is not accessible to the 

public and specifically prepared for performing test drives in order to reduce hazards. 

1.1.3  Disclaimer 

Claims based on defects and liability claims against G.i.N. GmbH are excluded to the extent damage or 

errors are caused by improper use of the device or use not according to its intended purpose. The same 

applies to damage or errors arising from insufficient training or lack of experience of personnel using the 

device. 
 

Certification 

G.i.N. Gesellschaft für industrielle Netzwerke GmbH has ISO 9001:2008 certification. The ISO standard is a 

globally recognized standard. 
 

Summary of Contents for GLA618

Page 1: ...GLA618 User Manual English...

Page 2: ......

Page 3: ...is solely responsible for any damages or losses of use that may occur as a result of using this manual If you notice any errors in this document or have any suggestions on how it could be improved pl...

Page 4: ...eatures 4 4 General 5 5 Scope of Delivery 5 6 Ports and Display Elements 6 6 1 Power Connector 6 6 2 AUX Connector 7 6 3 Relay Contacts and Fuse 7 6 4 LEDs 8 6 5 Control Button 9 6 6 Mini USB Interfac...

Page 5: ...n using the device safely To ensure the operation of the GLA618 connected cables should not exceed a length of 30 m 1 1 2 Hazards The device may control and or otherwise influence the behaviour of ele...

Page 6: ...n devices 1 x Mini USB for updating and configuration 1 x Status LED 8 x AUX Out Status LEDs 1 x Control Button for resetting the fuses and wake up of device 1 x Relay with fuse with a maximum thresho...

Page 7: ...tension devices to one data logger e g GL53xx 5 Scope of Delivery Before starting your first application please check if everything listed here is included in the delivery If any item is missing pleas...

Page 8: ...e chap 6 3 3 AUX In connector see chap 6 2 4 Mini USB interface see chap 6 6 5 Power connector see chap 6 1 Figure 2 1 Control button see chap 6 5 2 Operating status LED see chap 6 4 3 AUX Out status...

Page 9: ...a this data logger The output VBAT on AUX Out provides max 1 5 A and is supplied from the GLA618 power connector All lines on the AUX connector are equipped with filter elements for interference suppr...

Page 10: ...us of the fuse of the respective connector LED1 for AUX Out 1 LED8 for AUX Out 8 The status of the LEDs is defined as follows Operating State Operating State LED LED1 LED8 Device is off or in sleep mo...

Page 11: ...perating mode 6 6 Mini USB Interface This interface is used for connecting the GLA618 with the PC to update the firmware This is done with the maintenance program This program is included in the insta...

Page 12: ...8 has a fixed CAN interface which is equipped with a TJA1042T 3 CAN transceiver high speed This CAN interface is not able to wake up the device and is used for time synchronisation of the connected ex...

Page 13: ...and switched off by interrupting it During sleep mode the GLA618 wakes up when the control button is pressed During sleep mode the GLA618 wakes up via the data logger During sleep mode the GLA618 wak...

Page 14: ...LA618 User Manual Intelligente Datenlogger 9 Connection Plan The following figure shows the connection plan of a GLA618 connected to a data logger here GL53xx and three extension devices one GL5450 an...

Page 15: ...gente Datenlogger 10 Minimum Software and Hardware Requirements Before starting please check if the minimum requirements are fulfilled If something should be amiss or unclear do not hesitate to contac...

Page 16: ...e g overvoltage Operating the device near these limits over long stretches of time can also lead to damage or a shortened durability 11 1 Operating Condition All values specified are valid for the ful...

Page 17: ...C 15 G i N GmbH 2021 GLA618 User Manual Intelligente Datenlogger 12 Change History Datum Reference Description 11 2021 First Version...

Page 18: ...16 G i N GmbH 2021 GLA618 User Manual Intelligente Datenlogger Declaration of Conformity...

Reviews: