background image

         

 

Installing the DataSuite Software 

1.

 

DataSuite software is used to configure the MicroLogPRO II as well as download 

and analyze the recorded data. Download the DataSuite software from the 

www.fourtec.com

 homepage. 

2.

 

Run the setup file to install the Windows ® software on Windows XP, Vista or 7 

(32 or 64-bit). Follow the instructions to complete the installation. 

3.

 

Double-click the DataSuite desktop shortcut to launch the software. After the 

configuration screens are completed, connect the logger to the computer. 

Detecting the MicroLogPRO II 

 

1.

 

Only once the DataSuite software has been installed, connect the data logger 
via the mini-USB cable.   

2.

 

The logger will be automatically detected by the software and the logger icon 

will appear in the main DataSuite window, indicating it is ready for use: 

.  

Configuring the MicroLogPRO II using DataSuite Software 

1.

 

Right-click on the logger icon in the DataSuite window and select 

Setup

.  

2.

 

In the

 Properties

 tab, configure the relevant parameters e.g. sampling rate, 

temperature scale, operation mode, cyclic mode, unit comment, etc.  

3.

 

In the 

Sensors

 tab, select the relevant sensors and configure low and high 

alarm levels, if necessary. 

4.

 

From any tab, click 

Setup and Run

 to start logging. The MicroLogPRO II icon will 

appear as follows when in Run mode: 

.  

5.

 

To stop the logger when connected to the computer, right-click the 
MicroLogPRO II icon and select

 Stop 

from the context menu. 

 
 
  

 
 
 

 
MicroLogPRO II Layout  

 

* RH/Temp sensor for EC850 model only

 

General Specifications  

 

EC800 

EC850 

Internal Sensor Range: 

Temp:  
-40 to 80 

Temp: -40 to 80 

RH: 5 to 95 % 

Internal Temperature 
Accuracy: 

±0.3˚C @ 0 to 60 ˚C 
±0.3 ˚C @ -40 to 0 ˚C and 60 
to 80 ˚C 

after calibration only

 

± 0.3 °C 

Temperature Resolution: 

0.02 °C 

or better 

0.015 

Internal Humidity 
Accuracy & Resolution: 

NA 

± 2%, 0.05 % 

External Sensor Accuracy: 

NTC Temperature: 0.3 ˚C ; 4-20 mA: ±20 µA ; 0-10 V: ±5 mV 

External Sensor 
Resolution: 

NTC Temperature: 0.03 ˚C ; 4-20 mA: 1 µA (display), 4.0 µA 
(software) ; 0-10 V: 1 mV (display), 4.0 mV (software) 

Memory Capacity: 

 

52,000 samples (over 3 channels) 

Sampling Rate:

 

 

Minimum - Once every second; Maximum - Once every 18 hours 

Dew Point: 

NA 

LCD and Software indication 

LED: 

Bi-color Alarm 

Power Supply: 

2/3 AA 3.6V Lithium battery 

Standards Compliance: 

CE, IP65 

CE, IP54 

Bi-color LED

Min/Max Hours button

LCD screen

Min/Max Days button

Cradle for wall mounting

RH/Temp sensor 
location

External sensor input

Mini-USB input

Page 1 

MicroLogPRO II Quick Start Guide 

          www.fourtec.com | [email protected]             Rev B, Jan-14, © Fourtec – Fourier Technologies 

2012 

 

www.esis.com.au

Ph  02 9481 7420

Fax 02 9481 7267

[email protected]

Reviews: