Installing the DataSuite Software
1.
DataSuite software is used to configure the MicroLogPRO II as well as download
and analyze the recorded data. Download the DataSuite software from the
www.fourtec.com
homepage.
2.
Run the setup file to install the Windows ® software on Windows XP, Vista or 7
(32 or 64-bit). Follow the instructions to complete the installation.
3.
Double-click the DataSuite desktop shortcut to launch the software. After the
configuration screens are completed, connect the logger to the computer.
Detecting the MicroLogPRO II
1.
Only once the DataSuite software has been installed, connect the data logger
via the mini-USB cable.
2.
The logger will be automatically detected by the software and the logger icon
will appear in the main DataSuite window, indicating it is ready for use:
.
Configuring the MicroLogPRO II using DataSuite Software
1.
Right-click on the logger icon in the DataSuite window and select
Setup
.
2.
In the
Properties
tab, configure the relevant parameters e.g. sampling rate,
temperature scale, operation mode, cyclic mode, unit comment, etc.
3.
In the
Sensors
tab, select the relevant sensors and configure low and high
alarm levels, if necessary.
4.
From any tab, click
Setup and Run
to start logging. The MicroLogPRO II icon will
appear as follows when in Run mode:
.
5.
To stop the logger when connected to the computer, right-click the
MicroLogPRO II icon and select
Stop
from the context menu.
MicroLogPRO II Layout
* RH/Temp sensor for EC850 model only
General Specifications
EC800
EC850
Internal Sensor Range:
Temp:
-40 to 80
C
Temp: -40 to 80
C
RH: 5 to 95 %
Internal Temperature
Accuracy:
±0.3˚C @ 0 to 60 ˚C
±0.3 ˚C @ -40 to 0 ˚C and 60
to 80 ˚C
after calibration only
± 0.3 °C
Temperature Resolution:
0.02 °C
or better
0.015
C
Internal Humidity
Accuracy & Resolution:
NA
± 2%, 0.05 %
External Sensor Accuracy:
NTC Temperature: 0.3 ˚C ; 4-20 mA: ±20 µA ; 0-10 V: ±5 mV
External Sensor
Resolution:
NTC Temperature: 0.03 ˚C ; 4-20 mA: 1 µA (display), 4.0 µA
(software) ; 0-10 V: 1 mV (display), 4.0 mV (software)
Memory Capacity:
52,000 samples (over 3 channels)
Sampling Rate:
Minimum - Once every second; Maximum - Once every 18 hours
Dew Point:
NA
LCD and Software indication
LED:
Bi-color Alarm
Power Supply:
2/3 AA 3.6V Lithium battery
Standards Compliance:
CE, IP65
CE, IP54
Bi-color LED
Min/Max Hours button
LCD screen
Min/Max Days button
Cradle for wall mounting
RH/Temp sensor
location
External sensor input
Mini-USB input
Page 1
MicroLogPRO II Quick Start Guide
www.fourtec.com | [email protected] Rev B, Jan-14, © Fourtec – Fourier Technologies
2012
www.esis.com.au
Ph 02 9481 7420
Fax 02 9481 7267