![Gima TEMP SITTER User Manual Download Page 1](http://html1.mh-extra.com/html/gima/temp-sitter/temp-sitter_user-manual_2228222001.webp)
ITALIANO
The user should be aware that changes or modifications not explicitly
approved by the compliance manager may void the user’s permission to use
the device.
FCC DECLARAION:
• This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a residential environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Nevertheless, there is no guarantee that
interference may occur in certain installations.
• Should the device interfere with radio or television reception, which may
be detected by switching the device on and off, we encourage users to try
correcting the interference by carrying out one or more of the following
measures:
- Move or reposition the receiver aerial
- Increase the distance between the device and the receiver.
- Connect the device to a socket on a different electrical circuit to that of the
receiver.
- Contact a Radio/TV re-seller or expert technician for assistance.
Designated use
The device is designed for continuous measuring and monitoring of human
body temperature. It can store and manage temperature data. It can be used for
measuring under-arm temperatures in adults, children and newborns.
Appearance
Front view
Rear View
1. Under-arm temperature measurement sensor
Download and Install the Software
1 Methods for downloading the software:
• Users that use devices with the iOS operating system can log into the Apple
App Store and search for the “Temp Sitter” app. Alternatively, scan the iOS QR
code on the packaging to download.
• Users of the Android system can register on the official wearcare site:
http://www.wearcare.cn to download. Or, scan the Android WR code on the
packaging which takes you to the aforementioned website. With some Android
versions, it may be necessary to enable the installation of software from
non-Google Play sources.
2 Download the “Temp Sitter” software, click on the Install button for free
installation.
Instructions for Use
1 Enable Bluetooth on your smartphone or tablet (mobile terminal);
2 Remove the temperature sensor from the packaging. It will switch on a
utomatically and the illuminated indicator will flash rapidly;
3 Start the previously installed software. The device will connect automatically.
When connection is complete, the screen will display “Connection
Successful”.
4 Putting the temperature sensor on. The steps are as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
TEMP SITTER -
Baby wireless thermometer
PROFESSIONAL MEDICAL PRODUCTS
User manual
ATTENTION:
The operators must carefully read and completely understand the present manual before using the product.
Warnings for use
• No modifications to the device are permitted.
• Do not use the device together with other TAC or RM apparatus.
• Risk of Explosion: do not use the device on inflammable anaesthetic gases
• Do not crush the device. If the case is broken, stop using the device.
• Check the device regularly to ensure that it is in full contact with the skin;
otherwise measurements may be inaccurate.
• The device is for indoor use only.
• Pay attention to the temperature and humidity when operating. Use of the
device in conditions which do not comply with requirements could lead to
measurements being inaccurate.
• Wireless transmission is effective over 15m in an unobstructed area.
Over greater distances, the product may not function. Please use this product
within the wireless transmission distances indicated here.
• Muscle and fat influence wireless transmission; therefore the transmission
range will be lower if used by adults or overweight children.
• Magnetic and electrical fields may interfere with the correct operation
of the device. Therefore, ensure that all other devices operating near the
product comply with all Electromagnetic Compatibility (EMC) requirements.
Mobile telephones, X-ray or magnetic resonance equipment are possible
sources of interference, as they are capable of emitting higher levels
of electromagnetic radiation.
• The device is not sterile.
• Doctors should make diagnoses on clinical evidence and symptoms, and use
the device only as an accessory.
• This product has been calibrated. No further maintenance or calibration
is required, other than replacing the batteries.
• If the system needs upgrading, please update the program.
• The application will always be compatible with other applications in your
receiver. Please contact us if you come across this kind of problem.
• If you have any questions regarding the fitting, use or maintenance of this
device, or encounter any unexpected event, please contact the manufacturer
or its representatives.
• Please use and maintain the device according to this manual.
• We recommend that the user uses the original adhesives. We recommend
using the device in a cool environment for an improved sense of adaptation
to the person. If you feel unwell (discomfort or allergic reaction) during use
of the adhesives, please replace the adhesives with another type as advised
by a doctor.
• In the event of measurements over long periods of time, please check for
any skin allergies in the area. In the event of an allergic reaction, stop use
immediately.
• Please do not use adhesives that are supplied folded; use a new adhesive.
• Prepare the skin if used by an adult (e.g. hair removal).
• Please clean the surface of the device with 75% Concentration medical
alcohol before and after use. After removing the device, clean the skin that
was in contact with the device with medical alcohol. The material in contact
with the skin is non-toxic, hypo-allergenic, and will not cause allergic reactions
or any other side effects.
• To avoid interruptions caused by telephone calls or SMS during measurement,
we recommend activating Airplane Mode and Bluetooth on your iOS/Android
device (if a 3G SIM is installed).
• Contact with the device by animals or parasites could cause allergic reactions
or other collateral effects in the user. Please clean the surface of the device
with 75% concentration medical alcohol before use.
• Improper use by children could damage the temperature measurement sensor
and influence measurement accuracy.
• The temperature sensor activates and deactivates automatically. When you
remove the temperature sensor from the packaging, it activates automatically.
In the same way, it will switch off automatically when replaced in the
packaging.
• When the temperature sensor does not automatically connect to the
application connects to the mobile terminal software, the illuminated indicator
will flash twice periodically and will receive 2 notifications per minute (with the
application open or running in the background) of a dropped connection.
Once connected, it will flash once periodically.
The product has a temperature check suggestion function; users can set the
alarm value themselves.
• Only one device may be connected for data reception
The device is compliant with Part 15 of FCC regulations. Operation is subject
to the following two conditions:
1 This device cannot cause harmful interference;
2 This device must accept any external interference, including any such
interference which may cause undesired operation.
1
When the temperature
sensor connects to
mobile terminal application
software successfully, the
Bluetooth indicator light
will shine.
Paste the sticker
Paste the device
onto armpit
The measuring result will be transmitted to mobile terminal
application software immediately via wireless signal
transmission.
Open the packing
box and take out
the temperature
sensor
Gima S.p.A.
Via Marconi, 1 - 20060 Gessate (MI) Italy
[email protected] - [email protected]
www.gimaitaly.com