Otoscopio F.O. Sigma

Sigma F.O. Otoscope

Otoscope Sigma F.O. 

Sigma F.O. Otoskop

Sigma F.O. Otoscopio

Sigma F.O. Otoscópio

Σίγμα Φ.Ο Ωτοσκόπιο

MANUALE D’USO E MANUTENZIONE

USE AND MAINTENANCE BOOK

INSTRUCTIONS DE FONCIONNEMENT ET ENTRETIEN

BETRIEBS UND WARTUNGS ANWEISUNGEN

MANUAL DE USO Y MANTENIMIENTO

MANUAL DE USO E MANUTENÇÃO

ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ ΚΑΙ ΣΥΝΤΗΡΗΣΗΣ

ATTENZIONE:

 Gli operatori devono leggere e capire completamente questo manuale 

prima di utilizzare il prodotto.

ATTENTION:

 The operators must carefully read and completely understand the present 

manual before using the product.

AVIS:

 Les opérateurs doivent lire et bien comprendre ce manuel avant d’utiliser le produit.

ACHTUNG:

 Die Bediener müssen vorher dieses Handbuch gelesen und verstanden 

haben, bevor sie das Produkt benutzen.

ATENCIÓN:

 Los operadores tienen que leer y entender completamente este manual 

antes de utilizar el producto.

ATENÇÃO: 

Os operadores devem ler e entender completamente este manual antes 

de usar o produto.

ΠΡΟΣΟΧΗ:

 Οι χειριστές αυτού του προϊόντος πρέπει να διαβάσουν και να 

καταλάβουν πλήρως τις οδηγίες του εγχειριδίου πριν από την χρήση του.

Sigma F.O

ﻥﺫﻷﺍ ﺭﺎﻅﻧﻣ .

Gima S.p.A.

Via Marconi, 1 

20060 Gessate (MI) Italy

Made in U.A.E.

31524 - 31523 - 31525 

31526 - 31518

Fabbricante

Manufacturer

Teme l’umidità

Keep dry

Conservare al riparo della luce 

solare diretta

Keep away from sunlight

Apparecchio di Tipo B

Type B device

Summary of Contents for Sigma 31524

Page 1: ...ION The operators must carefully read and completely understand the present manual before using the product AVIS Les opérateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ACHTUNG Die Bediener müssen vorher dieses Handbuch gelesen und verstanden haben bevor sie das Produkt benutzen ATENCIÓN Los operadores tienen que leer y entender completamente este manual antes de utili...

Page 2: ...ation adaptor 10 Insuflation bulb Detalles del producto 1 Cabezal del otoscopio 2 Ventana de aumento 3 Puerto de insuflación 4 Interruptor de encendido apagado 5 Mango 6 Tapa inferior 7 Espéculo auricular desechable 8 Espéculo auricular reutilizable 9 Adaptador de insuflación 10 Balón de insuflación Détails de l instrument 1 Tête otoscope 2 Fenêtre d observation grossissante 3 Raccord de souffleri...

Page 3: ...εια Προϊόντος 1 Κεφαλή ωτοσκοπίου 2 Παράθυρο μεγέθυνσης 3 Θύρα εμφύσησης 4 Διακόπτηςενεργοποίησης απενεργοποίησης 5 Λαβή 6 Τελικό πώμα 7 Αναλώσιμος κώνος 8 Επαναχρησιμοποιημένος κώνος 9 Προσαρμογείς εμφύσησης 10 Λαμπτήρα εμφύσησης OFF ON A B C Fig 2 Fig 3 Lock 1 Fig 4 Led Fig 6 Insufflation Bulb connecting with Adaptor Insufflation Bulb Adaptor Fig 7 Peeloff Protectivesheet LensLockingPoint Fig 5 ...

Page 4: ... power source for Sigma instruments Grip the handle attached to Otoscope head To turn ON the light slide the switch with thumb towards the bottom of the handle To turn OFF the light slide the switch with thumb towards the top of the handle Fig 2 B Insert Batteries Arrange two AA LR6 size good quality alkaline batteries for power Rotate end cap counterclockwise to open the handle end cap Insert two...

Page 5: ...and cannot be changed because of its long life LED has 50 000 hours of extended lifetime Ensure no replacement of LED ever in the lifetime of the instrument Excellent light output of 85K LUX Extended battery life of 50 HOURS due to low current consumption of LED With a colour temperature of 5500K and CRI 80 colours are visible as they are Ear Tip Ear tip is used in otoscope as viewing passage for ...

Page 6: ...re and keep the instrument away from the range of insects and rodents Autoclaving is not permissible for this type of handle Ultrasonic cleaning is not recommended Store the device in clean environment at normal temperature Please ensure that the batteries Handles and Ear Tips and other Sub assemblies are discarded as clinical waste in accordance with local policies In accordance with local regula...

Page 7: ...dity of the warranty GIMA will repair and or replace free of charge all the defected parts due to production reasons Labor costs and personnel traveling expenses and packaging not included All components subject to wear are not included in the warranty The repair or replacement performed during the warranty period shall not extend the warranty The warranty is void in the following cases repairs pe...

Page 8: ...36 ...