background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

 

User's Manual 

Instructions for use 

 

This manual provides indications for safe use 

of the device. 

 

Before using the device, please: 

carefully read this manual.

 

MAYLEA  

Digital pressure massage 

28430 

 

Summary of Contents for MAYLEA 28430

Page 1: ...User s Manual Instructions for use This manual provides indications for safe use of the device Before using the device please carefully read this manual MAYLEA Digital pressure massage 28430 ...

Page 2: ...cription 7 Accessories 8 Standard accessories 8 Optional accessories 8 How to use the device 9 Features 9 Warnings for first use 9 Setting the pressure 10 Setting the timer 10 Setting the operating mode 11 Self Calibration 11 Connecting the hose to the air inlet 12 Using the leg arm cuff 13 Leg cuff extension optional 14 Technical and environmental features 15 Troubleshooting 16 Warranty 17 Dispos...

Page 3: ...e user must know in order to prevent any hazards that may occur Symbols key 1 In case of failure to comply with the instructions herein you expose yourself to severe injury and death hazard In case of failure to comply with the instructions herein the user may get seriously injured or damage the device Precautions Marks dangerous actions Forbidden Do not disassemble the device Forbidden to demount...

Page 4: ...ce please contact only authorized service centres Do not pull the power cable to disconnect the plug from the socket Do not connect or disconnect the supply plug if your hands are wet fire and electrocution hazards Do not damage bend or tangle the cable fire and electrocution hazards Disconnect the power supply plug before cleaning the device and during periods of inactivity Forbidden 2 Safety inf...

Page 5: ... with artificial joints metal inserts etc are not allowed to use the device Use the device according to physician s prescription on patients suffering from heart diseases inflammatory skin disorders pulmonary oedema fever or other particular health conditions Use the device according to physician s prescription on patients who undergone surgery and are not yet fully recovered Do not use the access...

Page 6: ...eep the device in horizontal position if tilted malfunctions may occur Forbidden Attention Precautions Forbidden Attention Do not use water oil benzene alcohol petrol chemical products etc The use of chemical products may damage the device and its accessories Clean with a dry cloth The user must not repair or demount the device Do not bend or scratch the air connection hose Be careful and prevent ...

Page 7: ...ssure 10 180mmHg 20mmHg Consumption 70VA Dimensions 190 L x250 d x210 h Weight 3Kg Only body 3 Product description Operating mode indicator Mode selection key Pressure dial Pressure display Channel indicator SKIP function setup key Start Stop key Timer setup keys Start button Air connector ...

Page 8: ...8 Standard accessories Optional accessories 4 Accessories single hose double hose Massage sole 28440 28435 Leg cuff Arm cuff Leg cuff extension 28434 28437 Waist pad 28436 ...

Page 9: ...rst use set the pressure to a value lower than 60mmHg for 10 minutes then gradually increase the pressure and the usage time based on user s conditions Leg cuff Put the leg cuff on keeping your leg straight If you straighten your leg after putting on the leg cuff you might feel pain to your knee Waist pad optional Wind the pad properly around your abdomen waist or hips Arm cuff Fix the arm cuff us...

Page 10: ...sses from the leg or arm cuff In case of air loss due to a hole the pressure sensor detects the outflow and after 15 20 seconds it automatically passes to the next chamber Setting the timer The timer can be set to the values below 10 20 30 40 minutes To decrease the pressure turn the pressure knob to left The set pressure value can be viewed on the LCD display To decrease the usage time press the ...

Page 11: ...B is repeated for two times and mode A for one time in reversed sequence from thigh to foot Self Calibration If you detect unusual conditions press the keys MODE SKIP and POWER at the same time You should perform a Self calibration every six months to adjust the pressure Setting the SKP function Press key 1 to select a channel indicated by led 2 Select the side or sides to be skipped using the key...

Page 12: ...oid any air losses 7 Connecting thehoses totheleg armcuff Insert the connectors in the leg cuff and in the arm cuff according to the colours The therapeutic effect will be altered if the connection is not made properly Inflation sequence Leg cuff foot calf knee thigh Arm cuff hand elbow forearm shoulder Waist pad hip waist abdomen pelvis ...

Page 13: ...nits at the same time Put the leg cuffs or arm cuffs on and connect the double hose to the air connector Completely insert the connector to avoid any air losses The use of both arm cuffs at the same time requires medical advice as it may increase the blood pressure Using the waist pad optional Put the waist pad on and connect the double hose to the air connector Completely insert the connector to ...

Page 14: ... cuff around the thigh To use the extension open the leg cuff hinge completely and then insert the extension using the hinges on the leg cuff and those on the extension STANDARD SET XL size with extension Thigh circumference 76 cm 86 cm Length 79 cm 79 cm 28435 OPTIONAL M size with zipped extension Thigh circumference 60 cm 70 cm Length 75 cm 75 cm ...

Page 15: ... the presence of flammable anaesthetics or oxygen 5 Operating mode continuous Environmental conditions for transport and storage Operating conditions Temperature C 0 40 Relative humidity 10 60 Atmospheric pressure hPa 700 1060 Transport and storage conditions Temperature C 20 60 Relative humidity 0 90 Atmospheric pressure hPa 500 1060 6 Technical and environmental features ...

Page 16: ... device is placed horizontally Remove any materials leaning on the device Check for any foreign objects or excess dust inside the device The air does not come out from the hose Make sure that the hose is not bent Make sure that the connector is properly inserted It remains blocked on a single phase for 20 seconds while inflating Make sure that the leg arm cuff is not punctured and that there are n...

Page 17: ...are consumables DESCRIPTION Compressed air system MODEL 28430 SERIALNUMBER WARRANTY 1 year PLACEOFPURCHASE PURCHASEDATE Disposal The product should not be disposed of as domestic waste The users must dispose of the devices by bringing them to waste collection points authorized for electrical and electronic devices recycling For more information on the collection points please contact the local aut...

Reviews: