background image

1

User’s Manual

Ultra-Portable Smart

Blood Pressure Monitor

Model BP1, BP1A

Summary of Contents for BP1

Page 1: ...1 User s Manual Ultra Portable Smart Blood Pressure Monitor Model BP1 BP1A ...

Page 2: ...loth or a cloth dampened with water and a neutral detergent Never use alcohol benzene thinner or other harsh chemicals to clean the device or cuff Avoid tightly folding the cuff or storing the hose tightly twisted for long periods as such treatment may shorten the life of the components The device and cuff are not water resistant Prevent rain sweat and water from soiling the device and cuff Do not...

Page 3: ...he cuff on an arm with another medical electrical equipment attached The equipment may not function properly People who have a severe circulatory deficit in the arm must consult a doctor before using the device to avoid medical problems Do not self diagnose the measurement results and start treatment by yourself Always consult your doctor for evaluation of the results and treatment Do not apply th...

Page 4: ...hone 4s iPad 3 and models launched subsequently or with Android software Hardware is Android 4 0 or above mobile phone or tablet with Bluetooth 4 0BLE 2 Introduction 2 1 Intended Use This product is intended for use in measuring blood pressure and pulse rate for adult patient population in home and hospital facilities 2 2 Contraindications This device is contraindicated for use in ambulatory envir...

Page 5: ...epresentative CE0197 CE Marking indicating conformance to EC directive No 93 42 EEC concerning medical devices Indicate separate collection for electrical and electronic equipment WEEE IP22 Protected against spraying water and against access to hazardous parts with a tool per IEC 60529 ...

Page 6: ...e monitor works in a very low power consumption and one charge usually works for months When the battery is low the indicator will be red flash On screen battery symbols which indicate the battery status can be seen on the APP Note The device cannot be used during charging 3 2LED indications Blue blink Powered on and Bluetooth is not connected Blue ON Bluetooth connected Red blink Low Battery Red ...

Page 7: ...ction of the upper arm caused by rolling up a shirtsleeve may prevent accurate readings 4 Confirm that the artery position mark is line up with the artery 3 4How to Sit Correctly To take a measurement you need to be relaxed and comfortably seated Sit in a chair with your legs uncrossed and your feet flat on the floor Place your arm on a table so the cuff is level with your heart Do not roll up shi...

Page 8: ... connect the monitor will be listed in the screen and just choose the right monitor to start the APP The monitor is identified by 4 numbers which should match with the 4 ending numbers of the device SN 3 Make sure the phone sound is ON and the volume is set to loud for a clear voice instruction 3 6Measurement Follow the text and voice guide on the phone to finish the measurement 1 Pump up the cuff...

Page 9: ...nt you should keep still and don t squeeze the bulb Stop measuring when the indicator turns red Otherwise the measurement may be effected and the blood pressure readings may be inaccurate 3 7After Measurement Press the exhaust valve to exhaust air from the cuff Press the button to turn off the power after the measurement Remove the cuff Note The device has an automatic power shut off function whic...

Page 10: ...r 5s Cannot get blood pressure readings The measurement is interrupted by arm movement or unexpected bulb squeeze Keep arm still and don t squeeze the bulb during deflating measu re phase There is an over leakage of press Check if the hose connection is loose 4 Accessories Model Description CU 10 Adult arm size 22 42cm 540 00240 00 MICRO USB charge cable Arm size The circumference at the biceps 5 ...

Page 11: ...40 C 25 to 70 C Relative humidity non condensin g 10 to 95 10 to 95 Barometric 700 to 1060 hPa 700 to 1060 hPa Degree of dust water resistance IP22 Physical Size 68mm long 25mm diamete r main unit Weight Less than 30 g main unit Cuff size Adult cuff 22 42cm Small adult cuff optional 17 22cm Adult cuff 22 32cm Wireless connectivity Built in Bluetooth 4 0 BLE Power Supply ...

Page 12: ...re measurement accuracy 3mmHg or 2 whichever is greater Pulse rate range 40 to 200 bpm Pulse rate accuracy 2 bpm or 2 whichever is greater Mobile APP APP function Guide measure display results store and share results IOS software hardware IOS 8 0 or above iPhone 4s iPad 3 and models launched subsequently Android software Hardware Android 4 0 or above mobile phone or tablet with Bluetooth 4 0BLE Bl...

Page 13: ...quipment The device needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided below Other devices may interfere with this device even though they meet the requirements of CISPR When the inputted signal is below the minimum amplitude provided in technical specifications erroneous measurements could result Portable and mobile com...

Page 14: ...ents including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions IEC61000 3 2 Class A Voltage Fluctuations Flicker Emissions IEC 61000 3 3 Complies Guidance and Declaration Electromagnetic Immunity The Blood pressure monitor is intended for use in the electromagnetic environment ...

Page 15: ... dips short Interruptions and Voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s Mains power quality should be that of a typical commercial or ...

Page 16: ...that it is used in such an environment as described below Immunit y test IEC606 01 test level Complian ce level Electromagnetic environment guidance Conduc ed RF IEC6100 0 4 6 3 Vrms 150 kHz to 80 MHz outside ISM bands 3 Vrms 150 kHz to 80 MHz outside ISM bands Portable and mobile RF communications equipment should be used no closer to any part of the system including cables than the recommended s...

Page 17: ...d by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey s...

Page 18: ...paration distance according to frequency of the transmitter m 150 kHz 80 MHz P d 2 1 80 MHz 800 MHz P d 2 1 800 MHz 2 5 GHz P d 3 2 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 20 1 20 2 30 10 3 80 3 80 7 30 100 12 00 12 00 23 00 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the fr...

Page 19: ...gy Co Ltd 4E Building 3 Tingwei industrial Park Honglang North 2nd Road Baoan 518100 Shenzhen P R China www viatomtech com info viatomtech com MedNet GmbH Borkstrasse 10 48163 Muenster Germany PN 550 01222 00 Version B June 2018 ...

Reviews: