Dear Customer,

thank you for purchasing this LED nystagmus spectacle. Please read this instruction carefully before using your new 

LED nystagmus spectacle carefully to ensure proper handling and long service life.

Other languages of the instructions for use can be found on our homepage www.dehag.com.

With the LED nystagmus spectacle it concerns an investigation instrument which serves to observe spontaneous quick 

ocular movements (nystagmus) with patients with disturbances of the balance sense.

Read the safety instructions carefully and still only use the LED nystagmus spectacle as described in this manual, so 

it does not accidentally come in injury or damage. Keep this instruction for use to the later checking up. With passing 

on of the LED nystagmus spectacle you also hand over this instruction for use.

Safety instructions

General

 • Please read this instructions carefully and retain them for reference.

•  Use this LED nystagmus spectacle solely in accordance with this instruction.

•  The lenses are very delicate, handle the LED nystagmus spectacle with great care.

•  Avoid placing the LED nystagmus spectacle on surfaces that could scratch the lenses.

•  Always place the LED nystagmus spectacle on the removable inlay in the outer carton.

•  The LED nystagmus spectacle may only be used by medical staff. This instruction do not replace a good medical 

education.

•  Misuse or any modification is not under the responsibility of the manufacturer.

•  Please check the LED nystagmus spectacle for functionality and integrity before each use.

•  Have any repairs carried out solely by a qualified electrician.

•  Please remove the batteries before sending the LED nystagmus spectacle.

•  Never try to repair the LED nystagmus spectacle yourself.

•  Repairs may only be carried out with original spare parts which are installed according to the intended use.

•  Any change leads to the exclusion of liability.

•  The CE-sign looses is validity in case of the use of any non original spare parts.

•  If you transfer the LED nystagmus spectacle to a third party, also hand over this instruction manual.

Warnings

•  Do not use damaged instruments!

•  Protect the LED nystagmus spectacle and its parts against all kind of mechanical damage or force!

•  Avoid hitting the lenses, which could break and cause damages!

•  Do not throw and use with care!

•  Screen the LED nystagmus spectacle and the accessoires from the sun. Keep dry! The products have to shelter 

from humidity about 75%!

•  Misuse, damage, and wear are not covered by the warranty!

•  Any signs or wear and tear due to regular use are excluded from the warranty!

•  Make absolutely sure that no liquid enters the battery handle or the LED nystagmus spectacle.

•  Make sure to use dry batteries only and that the handle is clean and dry before inserting batteries!

Intended use

Device for short-term examinations or for mobile use in the field of vertigo diagnostics.

Indication/Contraindication

Whether the use of LED nystagmus spectacle is indicated depends on the type of nystagmus examined. For example, 

LED nystagmus spectacle are used to assess spontaneous nystagmus, but are not suitable for observing directional 

nystagmus.

Side effects and residual risks

Contamination due to non-compliance with the preparation instructions, wrong or defective accessories.

Electricity

•  To ensure the power supply of the LED nystagmus spectacle, use three batteries of size C LR14/AM-2 (baby cells) 

á 1.5 volts.

•  When inserting the batteries make sure the poles are connected correctly.

Summary of Contents for 31207

Page 1: ...ly com export gimaitaly com www gimaitaly com È necessario segnalare qualsiasi incidente grave verificatosi in relazione al dispositivo medico da noi fornito al fabbricante e all autorità competente dello Stato membro in cui si ha sede All serious accidents concerning the medical device supplied by us must be reported to the manufacturer and competent autho rity of the member state where your regi...

Page 2: ...fore sending the LED nystagmus spectacle Never try to repair the LED nystagmus spectacle yourself Repairs may only be carried out with original spare parts which are installed according to the intended use Any change leads to the exclusion of liability The CE sign looses is validity in case of the use of any non original spare parts If you transfer the LED nystagmus spectacle to a third party also...

Page 3: ...ccurred due to improper handling during transport Your LED nystagmus spectacle package includes all of the following items If any of these items are missing please contact the dealer for assistance 1x LED nystagmus spectacle 1x user s instruction 1x carton 1x inlay Operation General With the purchase of the LED nystagmus spectacle type 803 823 you have the opportunity to do a short term exami nati...

Page 4: ... you will not be using the LED nystagmus spectacle for a prolonged period take the batteries out of the batte rie holder Deactivation activation of the switch off function To deactivate the switch off function hold down the timer button on the battery hold while turning on the rotary switch at the same time Release the timer after turning off the 30 sec LED approx 1 second and turn off the LED nys...

Page 5: ...aby cells type LR14 AM 2 á 1 5V Dimensions 223 x 150 x 70 mm3 Weight approx 400 g w o batteries Protection Class IP X0 Classification according to Classification Class I according to Annex VIII of Directive 2017 745 EU Classification Risk group I according to DIN EN 62471 CE marking according to Directive 2017 745 EU Classification RKI uncritical Storage and transport conditions Storage temperature 30...