2 WARNING

•  Power supply must be cut off when changing electrical components or maintaining and cleaning machines.

•  The plug must be plugged into an outlet that is properly installed and grounded, to prevent the risk of fire and electric shock.

•  Do not stand on this equipment.

•  Do not allow children to play with and place the equipment in a place where children can touch. Please adjust the backrest to the highest position 

when you leave.

•  Please do not place the equipment in wet places such as bathroom to avoid electric shock or other failure; Also keep the controllers away from 

water.

•  Please do not place and operate the equipment in places where is painting/coating or supplying oxygen.

•  Unless being monitored or instructed by personnel who can be responsible for their personal safety, the people who have physical obstacles, 

tactile disorders, mental disorders, lack of experience, common sense or children, are not allowed to use the equipment.

•  Please contact distributor, service center or related personal with appropriate skill and experience for repairing if the plug is damaged, in case 

of any danger.

•  Please make sure there is no accessible thing within the stroke during any operation of the beds.

•  Operation should be processed by trained professionals.

3 PRECAUTIONS

•  The equipment should be used by an experienced person who must be familiar with the product structure, performance and instructions. And 

make the regular maintenance work.

•  Read this manual carefully before installation, operation and adjustment. And please keep it well.

•  This product shall not be used for single side or single point loading work.

•  Comply with safety operation rules, do not overload the use of products, to ensure that the product safety protection equipment is complete and 

reliable, eliminates unsafe factors on time.

•  Tighten bolts and nuts regularly to avoid failure caused by loose, sliding, vibration and falling parts.

•  During the maintenance, the operator shall not disassemble any parts of the bed at will.

•  This product is not allowed to operate when it's with fault. If abnormal phenomenon or abnormal sound is found, it must be stopped for inspection 

immediately, and work can be resumed after troubleshooting.

•  The operator must be familiar with the precautions described in each section of the 

manual to ensure the safety of person and product.

•  This electric beauty bed is equipped with a three-wire power cord. The power cord 

must be plugged into a three-hole outlet which is properly installed and grounded. This 

is not only to prevent the risk of electric shock, but also ensure bed work properly.

•  Please operate the equipment strict accordance with the warning label pasted to the 

products.

•  While controlling the lifting of the whole bed, the button must be pressed continuously 

until the bed in a suitable position.

•  Please pay attention that the continuous working times should be Max. 2Min. ON ; 

18Min. OFF, when operating the motor.

•  Maintenance should be processed by trained professionals.

•  After each treatment, please use neutral reagent to clear the dust, stains on leather or 

on wood pieces.

•  When adjusting the backrest, seat cushion, footrest or lifting of the whole bed by hand 

controller or installed foot controller, please keep your hands, feet and head away from 

the position. (Please see right picture)

4 APPLICABLE RANGE

These electric beauty beds are suitable for beauty, massage and manicure treatment.

5 INSTALLATION

1. Put the bed to a proper location, according to the overall layout, the daylighting or artificial lightings and operation condition of the salon's or the 

home. And keep it in the clean, dry and cool environment.

2. Open the packing carton to check if the bed is intact and whether the accessories or spares are complete. Please contact distributor or us if 

there's any problem.

3. Installation

  Place the bed to the proper position. Please note that it is unnecessary to install extra screw on the floor to fasten the bed, because the original 

design has taken the stability performance into consideration. But please ensure the bed is placed on a firm and flat ground, so as to prevent 

any accident. If the bed rotates or slant due to rough ground, please adjust the four pieces of plastic feet (M10x30) and nuts (M10) by hexagon 

open-end wrench, which are fasten on the bottom panel, so as to ensure the bed is stable.

4. Connect the plug with power supply properly. (Details as shown below)

Summary of Contents for 2218B

Page 1: ...AL PRODUCTS 2218B 28047 28048 Importato da Imported by Importé par Importado por Gima S p A Via Marconi 1 20060 Gessate MI Italy gima gimaitaly com export gimaitaly com www gimaitaly com Fabbricante Manufacturer Fabricant Fabricante SILVERFOX CORPORATION LIMITED No 18 1st TongLe Road TangXia Town Pengjiang District JiangMen City GuangDong Province China Made in China ...

Page 2: ...n and falling parts During the maintenance the operator shall not disassemble any parts of the bed at will This product is not allowed to operate when it s with fault If abnormal phenomenon or abnormal sound is found it must be stopped for inspection immediately and work can be resumed after troubleshooting The operator must be familiar with the precautions described in each section of the manual ...

Page 3: ...nd the hand controller This beauty bed includes angle adjustment of the backrest angle adjustment of the seat cushion and lifting adjustment of the whole bed which is an overall and integral structure Details as shown below angle adjustment of the backrest lifting adjustment of the whole bed angle adjustment of the seat inclination footrest angle adjustment Air switch Connection box Hand controlle...

Page 4: ...ttons return to normal operation status 15 Safe lock button light 17 Power indicator Hand controller are connected with power supply properly indicator light is on Otherwise it won t light 18 One key reset button Press the button the backrest angle will automatically move to the maximum the seat cushion angle will automatically move to flat footrest will move down to the maximum the height of the ...

Page 5: ...e a year 10 CIRCUIT SYSTEM CONNECTION DIAGRAM ENGLISH Power AC 100 120V or AC 220 240V or AC 100 240V 50 60Hz Maximum Power 300W Environment Temperature 0 C 40 C Relative Humidity 30 90 Lifting Rated Load 175 kg Package Size 1410x690x670mm Net Weight 98kg 2218B Gross Weight 109kg 2218B Power Foot controller option Whole bed lifting motor Seat inclination motor Backrest motor Footrest motor Control...

Page 6: ... of the built in foot controller 3 Please contact maintenance center or supplier for trouble shooting 4 Poor quality of the rocker switch 5 Poor quality of the control box 6 Repture of motor tail 7 Motor was damaged 8 Pressing the button the bed did not move 1 Put the movable footrest close to the fixed footrest make sure the limit switch is closed and then press the buttons again 2 Open the fixed...