background image

LETTINO ELETTTRICO PER CENTRI BENESSERE

ELECTRIC BEAUTY BEDS

FAUTEUIL DE SOIN ESTHÉTIQUE ÉLECTRIQUE

CAMILLA DE BELLEZA ELÉCTRICA

M28047-M-Rev

.0-03.21

PROFESSIONAL MEDICAL PRODUCTS

2218B (28047 - 28048)

Importato da / Imported by / Importé par / Importado por: 

Gima S.p.A. 

Via Marconi, 1 - 20060 Gessate (MI) Italy

[email protected] - [email protected]

www.gimaitaly.com

Fabbricante / Manufacturer / Fabricant / Fabricante:

SILVERFOX CORPORATION LIMITED

No. 18, 1st TongLe Road, TangXia Town, Pengjiang District, 

JiangMen City, GuangDong Province, China

Made in China

Summary of Contents for 2218B

Page 1: ...AL PRODUCTS 2218B 28047 28048 Importato da Imported by Importé par Importado por Gima S p A Via Marconi 1 20060 Gessate MI Italy gima gimaitaly com export gimaitaly com www gimaitaly com Fabbricante Manufacturer Fabricant Fabricante SILVERFOX CORPORATION LIMITED No 18 1st TongLe Road TangXia Town Pengjiang District JiangMen City GuangDong Province China Made in China ...

Page 2: ...n and falling parts During the maintenance the operator shall not disassemble any parts of the bed at will This product is not allowed to operate when it s with fault If abnormal phenomenon or abnormal sound is found it must be stopped for inspection immediately and work can be resumed after troubleshooting The operator must be familiar with the precautions described in each section of the manual ...

Page 3: ...nd the hand controller This beauty bed includes angle adjustment of the backrest angle adjustment of the seat cushion and lifting adjustment of the whole bed which is an overall and integral structure Details as shown below angle adjustment of the backrest lifting adjustment of the whole bed angle adjustment of the seat inclination footrest angle adjustment Air switch Connection box Hand controlle...

Page 4: ...ttons return to normal operation status 15 Safe lock button light 17 Power indicator Hand controller are connected with power supply properly indicator light is on Otherwise it won t light 18 One key reset button Press the button the backrest angle will automatically move to the maximum the seat cushion angle will automatically move to flat footrest will move down to the maximum the height of the ...

Page 5: ...e a year 10 CIRCUIT SYSTEM CONNECTION DIAGRAM ENGLISH Power AC 100 120V or AC 220 240V or AC 100 240V 50 60Hz Maximum Power 300W Environment Temperature 0 C 40 C Relative Humidity 30 90 Lifting Rated Load 175 kg Package Size 1410x690x670mm Net Weight 98kg 2218B Gross Weight 109kg 2218B Power Foot controller option Whole bed lifting motor Seat inclination motor Backrest motor Footrest motor Control...

Page 6: ... of the built in foot controller 3 Please contact maintenance center or supplier for trouble shooting 4 Poor quality of the rocker switch 5 Poor quality of the control box 6 Repture of motor tail 7 Motor was damaged 8 Pressing the button the bed did not move 1 Put the movable footrest close to the fixed footrest make sure the limit switch is closed and then press the buttons again 2 Open the fixed...