Safety functions

Obstruction in opening direction 

If the door wing encounters an obstacle during the opening motion, the drive unit is 

stopped. The door wing is closed as soon as the hold-open time has expired. Upon 

the next opening motion, the door wing moves at the programmed opening speed up 

to the position where the obstacle has been detected and, provided that the latter has 

been removed in the meantime, from there at slow speed up to the programmed OPEN 

position. The following opening motion will then be carried out in the normal fashion.

Obstruction in closing direction

If the door wing encounters an obstacle during the closing motion, the drive unit is 

stopped and the door wing reopened up to the OPEN position. During the next closing 

motion, the door wing moves at the programmed closing speed up to the position 

where the obstacle has been detected and, provided that the latter has been removed 

in the meantime, from there at slow speed up to the CLOSED position. The following 

closing motion will then be carried out in the normal fashion.

Limitation of the power

The static driving power on the main closing edge is limited to 150 N.

Function in the event of a mains failure

In the event of a mains failure, the door can be manually opened and closed.

Summary of Contents for FDC-E

Page 1: ...Swing door drive unit FDC E Operator manual Original 0547 999 58b 2010 04 ...

Page 2: ...d out by the after sales service 4 TROUBLESHOOTING 5 PROLONGED OPERATING INTERRUPTION 6 SHUT DOWN DISPOSAL OF THE INSTALLATION 6 APPENDIX 8 Declaration of incorporation according to machinery directive These instructions use the following signs in order to point out certain dangers and important remarks Warning Involving danger to life and limb Attention A situation where material could be damaged...

Page 3: ...d the installation must be taken out of operation PRODUCT DESCRIPTION Normal operation The swing door drive unit FDC E allows an automatic opening and closing of swing doors The functional characteristics of the door can be determined by means of the program switch as well as the internal switches and potentiometers Program switch position 1 AUTOMATIC Automatic operating mode All the control eleme...

Page 4: ...e normal fashion Obstruction in closing direction If the door wing encounters an obstacle during the closing motion the drive unit is stopped and the door wing reopened up to the OPEN position During the next closing motion the door wing moves at the programmed closing speed up to the position where the obstacle has been detected and provided that the latter has been removed in the meantime from t...

Page 5: ...ng to be carried out by the operator Before carrying out any manipulations on the swing door drive unit the mains power supply must be disconnected The drive unit co vering must not be removed Never use running water or high pressure machines for cleaning the area of the drive unit Do not use any scratching tools nor any chemical cleaning agents Checking and maintenance to be carried out by the af...

Page 6: ...ive unit does not work Program switch Switch to position 1 Mains switch provided by Switch on customers switched off Power plug pulled out Plug in Fuse installed by Replace customers defective Buzzer sounds Functional fatal Contact the after error sales service ...

Page 7: ...ck into operation SHUT DOWN DISPOSAL OF THE INSTALLATION No particular measures have to be taken by the operator with regard to the shut down dismantling and disposal of the installation The installation must be disassembled into its individual parts in order to be able to recycle the different materials We advise you to entrust your after sales service with the dismantling and disposal of your in...

Page 8: ...rtner Manufacturer Gilgen Door Systems AG Freiburgstrasse 34 CH 3150 Schwarzenburg Phone 41 31 734 41 11 Fax 41 31 734 43 79 www gilgendoorsystems com info gilgends com Your after sales service Handed over to the operator Date Signature This document remains with the operator of the door installation ...

Page 9: ...e Machinery Directive 2006 42 EC Appendix I Articles 1 1 2 1 1 3 1 1 5 1 2 1 1 2 4 1 2 6 1 3 1 1 3 2 1 3 4 1 3 7 1 5 1 1 6 1 7 The technical documentation according to Appendix VII Part B has been established and will be transmitted to the authorized services in the form of electronic files upon justified request In addition the requirements specified in the directives for low voltage installation...

Reviews: