Gilbert 1999GT-230 Owner'S Manual Download Page 4

4582

4601

4514

6003

4528-S

4530-S

 

Models 601T-230 Don™, 601E-230 Executive™

INSTALLATION INSTRUCTIONS

1. LAMPS SHOULD BE IN A VERTICAL POSITION WHEN UNIT IS PROP-

ERLY INSTALLED.
2. 

FOR FLAT-WALL MOUNTING: 

USING A LEVEL AND PENCIL, DRAW 

A STRAIGHT 7" LINE APPROX. 5' ABOVE FLOOR. COME IN 1/4" FROM 

ONE  END  AND  MARK  ACROSS  THAT  LINE.  MEASURE  5  1/4"  FROM 

THAT POINT AND MAKE A SECOND MARK. MOUNT THE TWO SCREWS 

(PROVIDED)  AT  THE  CROSSPOINTS,  LEAVING  1/2"  OF  THE  SCREW 

STICKING OUT. SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT 

TO AC POWER. 
3. 

FOR CORNER MOUNTING: 

USING A LEVEL AND PENCIL, DRAW A 

STRAIGHT 8 1/2" LINE FROM THE CORNER IN BOTH DIRECTIONS, AP-

PROX. 5' ABOVE FLOOR. MAKE A CROSS MARK AT THE END OF BOTH 

LINES. MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, 

LEAVING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNT-

ING SCREWS AND CONNECT TO AC POWER.
4. AFTER MOUNTING UNIT, OPEN THE GUARD AND PUT THE 2 ADDI-

TIONAL SCREWS (PROVIDED) IN THE 2 SLOTS AT THE BOTTOM.
5. MODELS 601E & 601C (ONLY) MAY BE RECESS MOUNTED IN WALL.

NOTE:

 IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) 

AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLAS-

TIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

The Don™, Executive™, Custom™ and Junior™ 

are for use indoors to control flies and other flying 

insects. These models  have keyhole slots located 

on the back for wall or corner installation and should 

be mounted 6" to 12" above floor for best results.

To  recess  mount  the  Executive™  or  Custom™, 

remove wing nut at bottom of inner body (which 

contains all electrical components), pull out bottom 

of inner body, slide down and out. Mount outer case 

permanently into wall. Reverse process to insert 

inner body. 

INSTALLATION INSTRUCTIONS

1.  LAMPS  SHOULD  BE  IN  A  HORIZONTAL  POSITION  WHEN  UNIT  IS 

PROPERLY INSTALLED.
2. USING A LEVEL AND PENCIL, DRAW A STRAIGHT 33" LINE APPROX. 3' 

ABOVE FLOOR. COME IN 1/4" FROM ONE END AND MARK ACROSS THAT 

LINE. MEASURE 32" FROM THAT POINT AND MAKE A SECOND MARK. 

MOUNT THE TWO SCREWS (PROVIDED) AT THE CROSSPOINTS, LEAV-

ING 1/2" OF THE SCREW STICKING OUT. SLIDE UNIT ONTO MOUNTING 

SCREWS AND CONNECT TO AC POWER. 

NOTE:

 IF MOUNTING ON MASONRY, USE A 3/16" BIT (NOT PROVIDED) 

AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLAS-

TIC ANCHORS (PROVIDED) BEFORE MOUNTING THE TWO SCREWS.

The Flying Lion™ is a superior trap to control flies 

and other flying insects. Keyhole slots are located 

on back for wall installation. 

Generally speaking,  

the lower any trap is placed, the more effective 

it is against flies.

 The Flying Lion™ is normally 

mounted 24" above the floor. 

Model 711-230 Flying Lion™

4

PROFESSIONAL ELECTROCUTING LIGHT TRAP

INSTALLATION AND APPLICATION

REMOVE ALL PACKING MATERIALS BEFORE INSTALLATION

Traps may be place higher than recommended, however,

the lower any light trap is placed almost always makes it more effective against flies!

See also: gilbertinc.com.strategic.htm

MODEL: Gilbert® 711-230 "Flying Lion"

See Parts List (Page 15) For Part Descriptions

Summary of Contents for 1999GT-230

Page 1: ...ight traps have one such safety switch If lamp flickers try reversing the lamp s PROFESSIONAL FLYTRAPS Gilbert www gilbertinc com LIMITED 1 YEAR WARRANTY To the original purchaser of a new 230 volt Gilbert Insect Light Trap we warrant that we will replace or repair free of charge any part found by us to be defective in factory workmanship or material for a period of one year from date of purchase ...

Page 2: ...TION EXTERIOR FINISH GENERAL SPECIFICATIONS Underwriters LaboratorieslistedunitsdisplaytheU L trademarks and fully comply with standards established by O S H A U S D A and other inspection agencies Registered with the Environmental Protection Agency EPA Est 39032 AR 1 Each unit is equipped with the properly rated spectral energy lamp for maximum insect attractancy Lamp replacement should be the sa...

Page 3: ...E 230 VAC 50Hz BLUE BROWN BLUE BROWN LINE INPUT 230 VAC BLUE BROWN LINE INPUT 230 VAC 230V AC 50Hz WH5 230 BLUE BROWN LINE INPUT 230 VAC WH5 230 Flying Insects are highly attracted to our trap designs and the lamps we have selected Coupled with good integrated management procedures Gilbert traps provide unequaled flying insect control And a few even provide beauty and style Good strategy emphasize...

Page 4: ... mounted 6 to 12 above floor for best results To recess mount the Executive or Custom remove wing nut at bottom of inner body which contains all electrical components pull out bottom of inner body slide down and out Mount outer case permanently into wall Reverse process to insert inner body INSTALLATION INSTRUCTIONS 1 LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROPERLY INSTALLED 2 USING...

Page 5: ...514 4582 4601 6003 4526 2 5 MODEL Gilbert 601T 230 Don MODEL Gilbert 601E 230 Executive See Parts List Page 15 For Part Descriptions See Parts List Page 15 For Part Descriptions 4514 4601 4582 6003 4526 ...

Page 6: ...S 1 THIS UNIT IS DESIGNED FOR INDOOR USE ONLY 2 LAMPS SHOULD BE IN A HORIZONTAL POSITION WHEN UNIT IS PROP ERLY INSTALLED 3 USING A LEVELAND PENCIL DRAW A SRAIGHT 28 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE END AND MARK ACROSS THAT LINE MEASURE 27 FROM THAT POINT AND MAKE A SECOND MARK MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTIN...

Page 7: ... when there is not room for a low wall mounted trap Mount flush with ceiling or suspend from ceiling using eyebolts To replace lamps guard must be removed from tray side of trap by the removal of 4 screws MODEL Gilbert 607 230 Hall Stalker See Parts List Page 15 For Part Descriptions 7 Light traps will catch flies better when there is less sunlight to compete with Window tinting film will screen o...

Page 8: ...VER 4528 S 2 6011 2 4601 4614 4582 WORKHORSE 5 4530 S 2 6005 2 5009 2 SEE DETAIL A 4010 2 4041 4 4049 4 6033 PLUNGE 6062 2 KNOB TRAY 6027 53 DIVIDER 2 DETAIL A GROUND TERMINAL 8 32x1 4 RHMS SECURED BY 8 32 HEX NUT BACK PANEL MODEL Gilbert 705 230 Night Hawk See Parts List Page 15 For Part Descriptions Place wall mounted traps down low to best catch day flying insects like the housefly Ceiling trap...

Page 9: ...THE TWO PLASTIC ANCHORS PROVIDED BEFORE MOUNTING THE TWO SCREWS The Night Eagle features superior effectiveness against night flying insects especially those with large circular flight patterns This trap is most often used above and perpendicular to shipping recieving docks takecarenottolocateanytrapswhereadditionalinsects can be attracted into the facility Adding optional back reflector panel con...

Page 10: ...als physical exclusion and the strategic installation in non public areas of more powerful ILTs are all part of a good integrated pest management solution Venus will catch flies better when there is less sunlight to compete with She will do her best as the sun goes down The useofwindow tinting filmcanreduce theattractiveness ofwindows and thereby increase the effectiveness of any ILT Though gluebo...

Page 11: ...7 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE END AND MARK ACROSS THAT LINE MEASURE 16 FROM THAT POINT AND MAKE A SECOND MARK MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER 4 FOR VERTICALMOUNTING USINGALEVELAND PEN CIL DRAW A STRAIGHT 7 LINE 24 48 ABOVE FLOOR COME IN 1 4 FROM ONE ENDAND MARKACROSS THAT ...

Page 12: ...LEVEL AND PENCIL DRAW A STRAIGHT 9 LINE FROM THE CORNER IN BOTH DIRECTIONS 32 57 ABOVE FLOOR MEASURE 9 13 16 FROM THE CORNER AND MAKE A CROSS MARK ON BOTH LINES MOUNT THE TWO SCREWS PROVIDED AT THE CROSSPOINTS LEAVING 1 2 OF THE SCREW STICKING OUT SLIDE UNIT ONTO MOUNTING SCREWS AND CONNECT TO AC POWER NOTE IF MOUNTING ON MASONRY USE A 3 16 BIT NOT PROVIDED AND DRILL OUT THE TWO CROSS MARKS AND IN...

Page 13: ...3 16 BIT NOT PROVIDED AND DRILL OUT THE TWO CROSS MARKS AND INSERT THE TWO PLASTIC ANCHORS PROVIDED BE FORE MOUNTING THE TWO SCREWS 4 USE AS FREE STANDING PORTABLE HANDLE AND 3 MAR RESISTANT FEET The 219GT 230 Sticky Tiger has key hole slots located on back for wall instal lation usually mounted approximately 24 above floor The Tiger may also be used as a free standing portable see Guerrilla porta...

Page 14: ...E MOUNTING THE TWO SCREWS The 747GT 230 Sticky Bear features superior effectiveness for control of flies and other flying insects The Bear has key hole slots located on back for wall installation Generally speaking the lower any trap is placed the more effective it is against flies The Bear is normally mounted 24 above floor Two glueboards are normally placed in the catch tray of the trap 2 option...

Page 15: ... wires are touching each other Be sure there is sufficient gap between two wires Bend back into alignment 2 Disconnect power a Make sure high voltage leads are connected to the grid lugs b Remove the unit s cover by drilling out rivets on Model 601C 230 see specific instructions for removing inner body on page 4 Check all connections to and from transformer then retest 3 Replace See schematic Ligh...

Reviews: