Before Installing Passport System
Page 6
MDE-3839Q Passport™ System Installation Addendum · December 2020
System Requirements
This section provides the system requirements of the Passport system.
Electrical Service
System
Voltage Requirements Current Requirements
Uninterruptible Power Supply (UPS), Cashier
Workstation [CWS (refer to
120 VAC, 60 Hz
20 A (supplying two isolated
ground receptacles)
UPS, Combined CWS/Manager Workstation
(MWS), or Standalone MWS and Report Printer
(refer to
120 VAC, 60 Hz
20 A branch circuit (supplying four
isolated ground receptacles)
Notes: 1) Power two UPS units for a maximum of two CWS, per 20 A circuit.
2) Power one UPS unit for a maximum of one Combined CWS/MWS or Standalone MWS, and one Report
Printer, per 20 A circuit.
Aspect
Limits
Temperature*
50 to 104 °F (10 to 40 °C)
Relative Humidity
10 to 80%
Altitude
Sea level to 10,000’
*
Thermal printers must use Gilbarco-specified paper.
Operating Environment
Aspect
Limits
Temperature
-22 to 131 °F (-30 to 55 °C)
Relative Humidity
5 to 95% (non-condensing)
Altitude
Sea level to 30,000’
Storage Environment
Before Installing Passport System
This section provides the following information for installing a POS system:
•
•
on
•
on
•
on
Read this section thoroughly before installing the system.
Unpacking Equipment
Upon delivery, unpack all system devices and inspect each device for damage. Check device
Model and Serial Numbers with the packing list. You must report all evident shipping damage
to the carrier. Gilbarco warranty does not cover shipping damage.
Note: Damage resulting from improper storage voids the Gilbarco warranty.
After you have inspected the system equipment, store it indoors in its original shipping carton,
until the installation. This protects the equipment from dirt and damage.