background image

© 2015 Gilbarco Inc. 
7300 West Friendly Avenue · Post Office Box 22087
Greensboro, North Carolina 27420 
Phone (336) 547-5000 · 

http://www.gilbarco.com

 · Printed in the U.S.A.

MDE-3882B Conversion of the Universal Distribution Box [D-Box (PA0261XXXXXXX)]: RS-422 to Two-wire and 
Two-wire to RS-422 · November 2015

The Advantage

®

 Series, CRIND

®

, Encore

®

, Eclipse

®

, Legacy

®

, and Passport

®

 are registered trademarks of Gilbarco Inc. GOLD

SM

 is a 

service mark of Gilbarco Inc. PAM

 is a trademark of Gilbarco Inc. Phillips

®

 is a registered trademark of Phillips Screw Company.

Converting D-Box from Two-wire to RS-422

Figure 12: Jumper Settings - RS-422 Interface, M14301 Board, Two Inputs of 8 Loops 

     Each

Summary of Contents for PA0261

Page 1: ...Service Contractors ASCs Do not install this equipment unless you have proper training for installing equipment in a hazardous location IMPORTANT INFORMATION Table of Contents Topic Page Introduction...

Page 2: ...Area Q13850 100 2 3 Gender Mender Assembly Modular Jack to D Sub Q13180 11B 2 4 Assembly Screw Lock Connector D Sub Q10437 07 4 5 Cables PC Q13240 09 1 Conversion Kit Q13241 118 Required Reading Wher...

Page 3: ...Passport Service Manual MDE 3839 Passport System Installation Addendum Passport Note Ensure to read and understand the installation documentation for the dispensers being connected to the D Box Abbrev...

Page 4: ...ety tape cones or barricades at the affected unit s A total electrical shut off of the affected unit s Read the Manual Read understand and follow this manual and any other labels or related materials...

Page 5: ...onnel Compile the following information and inform emergency personnel Location of accident for example address front back of building and so on Nature of accident for example possible heart attack ru...

Page 6: ...r components Failure to use electrostatic precautions may damage electronic components and void warranty CAUTION 1 Inform the manager 2 Barricade the unit to be worked on 3 Failure to turn off the uni...

Page 7: ...f the R18810 G1 Cable s to port P102 for T17651 and port P102A B for M14301 on the PCBs Note the orientation of the cable 6 Change and verify the jump jack settings Configuration 8 Loops 1 Input 16 Lo...

Page 8: ...0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Converting D Box from RS 422 to Two wire Jumper Settings Following are the diagrams for jumper settings for T17651 and M14301 Boards...

Page 9: ...of the Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Page 9 Converting D Box from RS 422 to Two wire Figure 2 Jumper Settings TWI M14301 Board...

Page 10: ...of the Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Converting D Box from RS 422 to Two wire Figure 3 Jumper Settings TWI Dual T17651 Boards...

Page 11: ...he Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Page 11 Converting D Box from RS 422 to Two wire Figure 4 Jumper settings TWI M14301 Board Sin...

Page 12: ...on of the Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Converting D Box from RS 422 to Two wire Figure 5 Jumper Settings TWI Dual T17651 Board...

Page 13: ...the Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Page 13 Converting D Box from RS 422 to Two wire Figure 6 Jumper Settings TWI M14301 Board T...

Page 14: ...install shorter R19249 G1 Cable near the board at D Sub position and longer R19249 G2 Cable at D Sub position away from board Secure the cable with standoffs 5 For T17651 Board connect the other end...

Page 15: ...422 to Two wire and Two wire to RS 422 November 2015 Page 15 Converting D Box from Two wire to RS 422 Jumper Settings Following are the diagrams for jumper settings for T17651 and M14301 Boards Figur...

Page 16: ...of the Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Converting D Box from Two wire to RS 422 Figure 8 Jumper Settings RS 422 Interface M14301...

Page 17: ...sal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Page 17 Converting D Box from Two wire to RS 422 Figure 9 Jumper Settings RS 422 Interface Dual T17651...

Page 18: ...the Universal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Converting D Box from Two wire to RS 422 Figure 10 Jumper Settings RS 422 Interface M14301 Bo...

Page 19: ...sal Distribution Box D Box PA0261XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 Page 19 Converting D Box from Two wire to RS 422 Figure 11 Jumper Settings RS 422 Interface Dual T17651...

Page 20: ...XXXXXXX RS 422 to Two wire and Two wire to RS 422 November 2015 The Advantage Series CRIND Encore Eclipse Legacy and Passport are registered trademarks of Gilbarco Inc GOLDSM is a service mark of Gilb...

Reviews: