![GILBARCO VEEDER-ROOT K35489 Quick Start Manual Download Page 4](http://html1.mh-extra.com/html/gilbarco-veeder-root/k35489/k35489_quick-start-manual_2227136004.webp)
Installation
© 2003 Gilbarco Inc. • 7300 West Friendly Avenue • Post Office Box 22087 • Greensboro, North Carolina 27420 • Phone (336) 547-5000 •
MDE-3642A
April 2003
Printed in the U.S.A.
Installing Mechanical Totalizer
1
Install T18464-GX cover plate and totalizer gear assembly
(8) onto pulser drive shaft (5).
Note: Parts fit snugly. Lubricate inner surface of
bushing with a small amount of lithium grease, if
necessary. If bushing (6) comes out, use a drift pin to
carefully replace bushing.
2
Install and tighten the two screws (7) securing the cover
plate (8) to the air gap plate (9).
3
Install N20965-12 counter gear (3) and K77558-28 cotter
pin (4) onto the pulser drive shaft (5).
4
Position the pulser (1) on the pulser drive shaft (5) and
secure with cotter pin (2).
5
Close the main door.
Testing Totalizer
1
Return the unit to operation.
2
Dispense 5 gallons of fuel into an approved container.
Compare electronic totals to mechanical totals.
1
2
3
4
5
6
7
8
9
G
A
S