background image

 

Capricorn S2X MEC Installation Note 

 

DCP0000247(C)

 

 
This installation note is applicable for SkyEdge II-c Capricorn S2X MEC CPE. The Capricorn S2X MEC CPE 
includes an embedded MEC unit (general processor board) treated as an external PC.  
 
To install the SkyEdge II-c Capricorn S2X MEC CPE, the installer must:  

 

Be trained in how to install the SkyEdge II-c Capricorn S2X MEC CPE 

 

Be familiar with the SkyEdge II-c CPE Installation Manual (DC-103322-X) 

 

Have the CPE configuration parameters available

 

 
The SkyEdge II-c Capricorn S2X MEC CPE is designed to be installed on a shelf in a 19-inch rack, secured to the 
cabinet by the rack-mount ears. 
The CPE can be installed with either front or rear panel facing forward. By default, the CPE is supplied with rack-
mount front ears secured to the front panel. The installation kit includes an additional pair of rack-mount back ears for 
securing to the CPE rear panel to install the CPE with the rear panel facing forward. The CPE may contain a built DC 
Inserter.  
 

Unpacking Guidelines 

1.

 

Unpack the Capricorn S2X MEC CPE unit and its accessories. 

2.

 

Compare with the supplied BOM and verify that all the items are supplied in good condition. 
 

 

VSAT AC and DC power supplies are provided by Gilat. If the power to the VSAT is not through 
an AC or DC adaptor (e.g., batteries, solar panels, rectifier ETC), the power solution must be 
approved by the Gilat Technical Support. 

 

 

C

AUTION

 

 

T

HE 

CPE

 MUST BE GROUNDED PRIOR TO INSTALLATION BY ATTACHING ONE END OF THE GROUNDING 

CABLE  TO  THE  GROUNDING  STUD  ON  THE  REAR  OF  THE 

CPE,

  AND  THE  OTHER  END  TO  THE  SITE  MAIN 

GROUND CONNECTION

.

 

18AWG

 GROUNDING CABLE SHOULD BE USED

 

T

HE 

CPE

 MUST BE CONFIGURED PRIOR TO ATTACHING THE 

RF

 CABLES

 

T

HE POWER CABLE MUST BE DISCONNECTED FROM THE 

CPE

 PRIOR TO CONNECTING THE 

RF

 CABLES

.

 

 

 

 
General Precautions 

 

Do not block the ventilation openings of the CPE. 

 

Do not place the CPE in a location that would deviate from typical ambient environmental conditions of 
temperature, humidity, and moisture. 

 

Do not place any object on top of the CPE. 

 

  

 

Warning 

B

EFORE INSTALLING THE UNIT

,

 VERIFY THAT THE ANTENNA AND 

AC

 POWER CORD ARE GROUNDED TO 

PROVIDE PROTECTION AGAINST VOLTAGE SURGES AND STATIC CHARGES

S

ECTION 

810

 OF THE 

US

 

N

ATIONAL 

E

LECTRICAL 

C

ODE

,

 

ANSI/NFPA

 

70,

 AND 

S

ECTION 

54

 OF THE 

C

ANADIAN 

E

LECTRICAL 

C

ODE PROVIDE INFORMATION REGARDING PROPER GROUNDING OF THE MAST AND 

SUPPORTING STRUCTURE

,

 GROUNDING OF THE LEAD

-

IN WIRE TO AN ANTENNA DISCHARGE UNIT

,

 SIZE OF 

GROUNDING CONDUCTORS

,

 LOCATION OF ANTENNA DISCHARGE UNIT

,

 CONNECTION TO GROUNDING 

ELECTRODES AND REQUIREMENTS FOR THE GROUNDING ELECTRODE

.

 

 

Connecting the LAN Cable

 

Use the CAT-5 type cables (approved by Gilat) to connect to the LAN ports.  
Use the LAN LEDs indicators to make sure that the LAN ports are operational. 

 
Connecting the Grounding Cable 

Connect the grounding cable (GND) from the CPE to the approved site.

 

 