Capricorn Pro 4 Installation Note
2
DCP0000250(B)
The Capricorn CPE can be powered in local AC power. The power connection is as follows:
•
For AC power, use the power cord supplied by Gilat.
•
In case of dual power supplies connect both inputs to the relevant power sources.
•
AC Main source: “readily accessible two pole circuit breakers should be provided in the building installation",
Rated 5A.
Connecting LAN Cable
Use only CAT-5 type cables to connect to the LAN port.
Connecting RF Cable
Connect the two RF cables (from the LNB and ODU) to the RF-IN and RF-OUT connectors, respectively, as shown
below, using a recommended torque of 13 lb*ft/in (1.5 N/m).
C
AUTION
T
O PREVENT DAMAGE TO THE
RF
C
ONNECTORS
,
SECURE THE CABLES TO A PERMANENT
,
STATIC OBJECT
SUCH AS A TABLE OR PIPE
,
AT A DISTANCE OF
25-60
CM
(10-25
IN
.)
FROM THE
CPE,
PRIOR TO CONNECTION
.
Figure 1: Capricorn Cables
Figure 2: Capricorn Rack-Mount
(Optional) Attaching Rack Mount Back Ears
To install the CPE with the rear panel facing forward:
1.
Remove the screws holding the rack-mount front
ears.
2.
Remove the rack-mount front ears.
3.
Secure the screws to the front panel.
4.
Remove the screws from the rear panel.
5.
Unpack the rack-mount back ears from the
installation kit
6.
Install the rack-mount back ears to the rear panel and
tighten the screws.